9
en
Emptying the collection receptacle/
Replacing the filter insert (GIBE
–
Figure D).
➤
Loosen the hose clamp (5) of the rear extraction
hose and pull off the extraction hose from the con-
nection sleeve (13).
➤
Loosen both star-knob bolts (12) and completely
pull out the collection receptacle (10).
➤
Loosen the six screws (11) until the frame (7) and
the filter inserts (8)/(9) can be pulled out to the rear.
➤
Clean the filter insert with compressed air and empty
the collection receptacle.
➤
Place the cleaned filter inserts (8)/(9) into the
frame (7) with the correct side facing upward.
➤
Reassemble all components in reverse order.
Repair and customer service.
Repairs may be carried out only by qualified per-
sons in conformity with the valid regulations.
For repairs, we recommend our FEIN customer service
centre, the FEIN authorised service centres and FEIN
agencies.
Carry out the following maintenance regularly:
➤
Empty the collection receptacle and clean the filter
inserts.
Replace the filter inserts in time when the extrac-
tion performance decreases.
➤
Remove any deposits from within the housing.
➤
Clean the movable parts of the support (2) with
compressed air.
Warranty and liability.
The warranty for the product is valid in accordance with
the legal regulations in the country where it is marketed.
In addition, FEIN also provides a guarantee in accordance
with the FEIN manufacturer’s guarantee. For further
details on this, please contact your specialist dealer, your
national FEIN representative, or the FEIN customer serv-
ice centre.
Declaration of conformity.
GRIT declares itself solely responsible for this product
conforming with the relevant provisions given on the last
page of this Instruction Manual.
Original language English/German
Environmental protection, disposal.
Stationary machines should be sorted for environment-
friendly recycling in accordance with national laws.
Noise emission values (GIBE).
REMARK: The sum of the measured emission value and
respective measuring inaccuracy represents the upper
limit of the values that can occur during measuring.
Wear ear protection!
Measured values determined in accordance with the cor-
responding product standard (see last page in this
Instruction Manual).
Specifications.
Connection diagrams.
Type GIBE, Appendix 48
Idle
Grinding
A-weighted emission pres-
sure power level measured
at the workplace L
pA
(re 20 µPa), in decibels
80.5
94
Measuring uncertainty K
wA
,
in decibels
4
4
Measured A-weighted sound
power level L
wA
(re 1 pW),
in decibels
90
100.5
Measuring uncertainty K
pA
,
in decibels
2.5
2.5
Operating conditions
GI150 mounted on GIBE
Speed
[
rpm
]
3000
3000
Material
–
ST 37
Dimension
–
8 x 40
Grinding belt
–
Grit by
FEIN 36R
Type
GIB
GIBE
GIBE
Reference number 9 90 0..
..1 003 00 0
..1 004 00 0
..1 004 00 0
Blower speed
[
rpm
]
–
2 880
3 450
Power input
[
W
]
–
370
370
Voltage
[
V
]
–
3x400/
3x230
3x440/
3x220
Frequency
[
Hz
]
–
50
60
Air flow
[
m
3
/h
]
–
800
800
Extraction vacuum
[
Pa
]
–
400
400
Weight according to EPTA-Procedure 01/2003
[
kg
]
17
55
55
Class of protection
–
I/ I/
3 94 10 004 00 0.book Seite 9 Mittwoch, 23. März 2011 4:22 16