Test and diagnostics options
Fault
Remedy
Suction turbine does not run
Switch on the appliance.
Check the mains cable, plug, fuse, socket and fill level sensors
Operating mode selector switch is set to ‘Automatic Start/Stop’.
Set the operating mode selector switch to the ‘Vacuum’ symbol and
switch on the power tool that is connected to the socket.
Check/replace the appliance switch. Check the socket.
Check/replace the control board.
Container is full in wet operation. Empty the container.
Empty the container.
Suction turbine switches off
Switch off the suction and wait for five seconds. Switch back on
after five seconds.
Suction turbine does not restart
after emptying the container.
Clean the fill level sensors and the space between the fill level
sensors with a brush.
Suction power drops
Remove the obstruction from the suction nozzle, pipe, hose or flat-
fold filter.
Change the disposal bag/dust bag.
Install the filter cover correctly.
Place the extractor top correctly and close locks.
Check the suction system for leaks.
Change the fleece filter bag.
Change the flat filter.
Check the vacuum with the pressure gauge on the tool collar.
Vacuum minimum 200 mbar.
Dust escapes when vacuuming
Check that the flat-fold filter is inserted correctly.
Change the flat-fold filter.
Automatic shut-down (wet
extraction) does not respond
Clean the fill level sensors and the space between the fill level
sensors with a brush.
Automatic shutdown does not function with electrically non-
conductive liquids or foam formation. Check the fill level regularly.