17
en
Handling the battery.
Operate and charge the battery only within
the battery operating-temperature range of
0°C – 45°C (32°F – 113°F). At the begin-
ning of the charging procedure, the battery
temperature must be within the battery oper-
ating-temperature range.
Battery charge-control indicator
(figure 11).
Press the button to activate the LED indica-
tion.
The real percentage of the battery charge
condition is only indicated when the power
tool motor is stopped.
The electronics automatically switch off the
motor prior to the battery being deep dis-
charged.
LED indi-
cator
Meaning
Activity
1 – 4
green LED
Percentage
of charge
condition
Operation
Continu-
ous red
light
Battery is
almost
empty
Charge battery
Red flash-
ing light
Battery is
not ready
for opera-
tion
Bring the battery
into the battery
operating-temper-
ature range, then
charge
100 %
75 %
50 %
25 %
0 %
LED indication on battery
Fig. 11
OBJ_BUCH-0000000113-001.book Page 17 Wednesday, April 17, 2013 10:01 AM