Adjustments.
Before mounting or replacing application tools or accessories, remove the bat-
tery.
This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Setting the torque (figure 9).
Open the cover using a screwdriver.
Turn the tool holder until the hole can be
seen under the cover.
Adjust the desired torque with the torque
setting tool.
Turn in the direction of the “+” to increase
the torque.
Turn in the direction of the “–” to reduce the
torque.
Shut the cover again.