Microscope C-Mount & Objectives:

LWD Plan Achromat

Semi APO 

Brightfield

Objective Type

Part # / Magnification

Numerical Aperture

Working Distance

FMPLN5 / 5x

FMPLN10 / 10x 

FMPLN20 / 20x

FMPLN50 / 50x

0.15

0.30

0.45

0.55

10.8mm

12.2mm

4mm

7.9mm

BF-SAPO-M20 / 20x

0.50
0.80
0.90

3.2mm
1.2mm

1mm

BF-SAPO-M5 / 5x

0.15

19.5mm

BF-SAPO-M10 / 10x

0.30

10.9mm

BF-SAPO-M50 / 50x

BF-SAPO-M100 / 100x

 

Using the C-Mount Adapter

Loosen the set screw (1) on the trinocular port and remove the 

dust cover (2).

Remove the dust covers from the c-mount adapter (3) and place 

the c-mount on the trinocular port, tightening the set screw (1).

Loosen the set screw (4) on the c-mount adapter to remove the 

c-mount (5). Connect the camera and then replace the c-mount 

adapter.

Adjust the image through the eyepieces and then pull the beam 

splitter to direct light to the camera. If the camera image is not 

clear, adjust the c-mount focus (6) until the image is clear in both 

the eyepieces and the camera at the same time.

Содержание Mi40

Страница 1: ...Mi40 Microscope User s Manual for Inverted Metallurgical Microscopes info feinoptic com...

Страница 2: ...ents Trinocular Port Fixed Stage Eyepieces Metal Stage Halogen Bulb Horizontal Adjustment Screw Field Diaphragm Centering Screw Power Switch Fine Focus Coarse Focus Coarse Tension Adjustment Beam Spli...

Страница 3: ...omponents Carrying Handle Polarizer 360 Rotating Analyzer Trinocular Port Diopter Adjustment Metallurgical Objectives Rheostat Control Aperture Diaphragm Adjustment Field Diaphragm Adjustment Fine Foc...

Страница 4: ...info feinoptic com Page 3 Microscope Assembly Follow the numbered diagram below when assembling the microscope 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 5: ...ugh room for any heat to dissipate Before replacing the fuse make sure the power switch 4 is in the O off position Voltage range of 100 240V is supported Make sure voltage is in this range Only use th...

Страница 6: ...the Objectives Rotate the coarse focus knob 1 until the nospiece is in it s lowest location Install the objectives 2 into the microscope nosepiece from the lowest magnification to the highest in a clo...

Страница 7: ...lot 3 on the illuminator connector panel It should click into place Reattach the handle 2 that was removed in order to slide the slider into the slot Assemble the Metal Stage Insert Insert the metal s...

Страница 8: ...Y Axis adjustment 6 in order to move the sample to the desired location Working range is 120mm x 80mm Connect the Power Supply Ensure the main switch is in the O off position Insert one side of the wi...

Страница 9: ...the sample on the stage and move the 5x objective into the light path The surface of the sample should be perpendicular to the objective Adjust the right diopter adjustment ring to 0 and look through...

Страница 10: ...gm The image of the field diaphragm can be seen through the eyetube Adjust the right and left centering screws 2 on the field diaphragm until the image is centered Open the field diaphragm slowly If t...

Страница 11: ...ust the filament to the center of the field of view for even illumination Shift the ground glass slider 1 out of the optical path until it clicks Set the field diaphragm lever 4 and the aperture diaph...

Страница 12: ...x Using the C Mount Adapter Loosen the set screw 1 on the trinocular port and remove the dust cover 2 Remove the dust covers from the c mount adapter 3 and place the c mount on the trinocular port tig...

Страница 13: ...rtical to the objective Adjust sample Aperture diaphragm not open Clean eyepiece objective Beam splitter is not in correct position Adjust beam splitter One side of field of view is dark or the image...

Страница 14: ...ck wire connections and connector pins for the bulb Bulb flickers or the brightness is not stable Coarse focusing knob is too tight Tension knob is too tight Loosen tension knob slightly Light does no...

Страница 15: ...lver screw on the light housing as shown at right The panel will open Remove the panel Depress the gold prongs as shown below and insert the bulb using a glove or lens tissue paper do not touch the bu...

Отзывы: