OBID i-
scan
®
Installation
ID ISC.LRU3000
FEIG ELECTRONIC GmbH
Page 45 of 52
LRU3000 - Manual.doc
E N G L I S H
Green
Yellow
Red
Description
Configurations-Reset:
FLASH
FLASH
FLASH
(light in sequence)
While T1 is pushed and hold for maximal 5s
ON
ON
ON
After T1 has been pushed and hold for 5s. Configuration
Reset has been finished.
Input / Output LED (yellow):
Configurable LED.
Can display the status of a digital input or output
ANT 1 – 4:
Green
HF Power switched on
Blue
Tag-Detect
Red
Antenna impedance error (> 50Ohm or <50Ohm)
Table 12 Configuration of the status LED’s
10.2 Reset-Push Button
Fig. 17 shows the position of the reset push button’s T1 and T2.
At the right side of the connector X6 the push button T2 is positioned. With this push button a CPU-
Reset can be performed.
With the push button T1 within the reader housing on left side of X3 a complete configuration reset
can be performed. For performing a reset you should use a paper clip and push the button T1 for
at least 5 s until the 3 status LED’s (left side) are switched on continuously, see
10.1.Status LEDs
Fig. 17 Position of the reset-switches T1 and T2