7.3 Selection of sensitivity
The following detuning values refer to a standard passenger car.
a) Detectors with 8 sensitivity levels
(e.g. VEK V2A, VEK M2B)
Indicated
detuning
Recommended
sensitivity level
> 2000
1
1600 – 2000
2
1200 – 1600
3
800 – 1200
4
400 – 800
5
200 – 400
6
100 – 200
7
< 100
8
b) Detectors with 4 sensitivity levels
(z.B. VEK M2E, VEK M1E)
Indicated
detuning
Recommended
sensitivity level
>1600
low
800 – 1600
med. low
200 – 800
med. high
< 200
high
7.4 Order data
a) VEK FG2 A Diagnostic set
Order No. 544
- Diagnostic device VEK FG2,
- Plug power pack
- 9V-accumulator
- Cable-M
- Cable-V
– Service box
b) VEK FG2 B Diagnostic set
O
rder No. 543
just like a), but with an additional
- LCR-meter with test strings
c) VEK FG LCR Diagnostic measuring instrument
order No. 546
- LCR- meter, suitable for service box
d) VEK FG ISO ground tester
order no. 586
- ground tester with test strings and
ever-ready case
e) VEK FG2 S3/M8 diagnostic cable
order no. 548
- Cable M9: 9-pole diagnostic cable for VEK S3 and VEK M8ER
f) VEK FG2 SVEK Diagnostic cable
order no
.
782
- Cable M4: 4-pole diagnostic cable for TST SVEKx