TST
Assembly instructions
FUF2 / FU3F -A/-C/-F
FEIG ELECTRONIC GmbH
page 87 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
No.
Description
Possible reason for error
F.389
Safety input incorrectly parametrized
• A safety edge is connected but deactivated
• With FUZ2: Safety input Jumper incorrectly set (as digital input jumpered but
as safety edge set)
F.38A
Redundancy error of the 8K2 slip door switch on the
second internal safety edge evaluation unit
• One of the contacts of the redundant 8k2 slip door switch is defective
• The slip door was not fully opened or closed
F.3A1
Number of trips for safety input A has reached set
limit
• Parameterized, maximum number of safety input
trips during a door cycle
was exceeded
F.3B1
Number of trips for safety input B has reached set
limit
• Parameterized, maximum number of safety input trips during a door cycle
was exceeded
F.3C1
Number of trips for safety input C has reached set
limit
• Parameterized, maximum number of safety input trips during a door cycle
was exceeded
F.3F4
2nd external safety edge - testing failed
• Pre
-limit switch for safety edge incorrectly set or defective
• Processing module defective
• Safety edge
defective
F.400
Controller hardware reset detected
• Strong interferences on the supply voltage
• Internal watchdog has triggered
• RAM error
F.401
Watchdog Error
• Internal Watchdog has released
F.409
RFUxK software incompatible
Only the expansion board RFUxK-F with the software version from V1. 11 can
be operated in parallel with other xpansion boards on a CAN-bus.
- The software version of the expansion board RFUxK-A/E is less than V1. 11
- the expansion boards are connected to different CAN interfaces (e.g. RFUxK-
A/E to CAN1 or CAN2 and RFUxK-F to CAN2 or CAN1)
F.40A
internal Software Reset
unplanned software reset of the processor
F.40B
Communication error expansion board
• The communication between main board and
expansion board is disturbed
F.40C
Unknown extension board (CAN connection)
• Incorrect hardware coding of the extension board
• Control software does not support the expansion card
• Expansion card defective
F.410
Over-current (motor current or DC-bus)
• Wrong motor data set (P.100 –
P.103)
• Non
-adjusted voltage increase / boost set (P.140 or P.145)
• Motor not properly dimensioned for door
• Door sticks
F.413
The brake chopper under heavy load
The brake chopper has to withstand heavy loads. The trip is interrupted to give
the chopper an opportunity to cool down. The fault resets itself after cooling.