M80601-4e-ID-B.docx
4.1.5. Switching over
“HID-Mode” and “Standard Mode” (ID ISC.PRHD102-B only)
Up from firmware version v01.06.00 the reader firmware supports additionally the “HID Mode”
(Keyboard Mode). Its behavior is like the output of the USB variant of this reader. It is similar like a
keyboard wedge. Default the reader has configured the “Standard Mode” for the output of the data.
For switching the reader over between the two output modes you must press the “Reset-button”
before using the “Scan-button” to power on the device. This is shown in figure 7.
After the device was powered up release the “Reset-button”. Now the reader will toggle the output
mode to “HID-Mode”. If you want to switch back the “Standard Mode” you must switch off the read-
er by double click on the “Scan-button” and repeat the above described procedure again. The
reader will remain in the output mode you’ve configured last till you start the procedure again to
change the output mode.
NOTE:
The pairing of PRHD102-B reader and a Bluetooth dongle should be done in “Standard
Mode”!
If the reader is in “HID Mode” and the reader already has established a connection to a Bluetooth
dongle an orange LED, flashing once every 10sec. signs that the reader firmware is currently con-
figured in “HID Mode”!
Figure 7: Switching over – HID Mode / Standard Mode