OBID
i-scan
®
UHF
Installation
ID ISC.PRHD102
FEIG ELECTRONIC GmbH
Page 14 of 23
M80601-4e-ID-B.docx
4.1.4. Reset - button (ID ISC.PRHD102-B only)
The Reader has a reset button. Below the yellow Scan button is a small hole in the housing. Below
this is the Reset button. On the one hand you can restore the Bluetooth settings to their original
configuration on the other hand you can clear a existing “paired connection” entry.
1. Reset Bluetooth parameters of the reader to its factory settings
After activating the Reader with the Scan button the Reader is reset to its factory settings by
holding the Reset button and the Scan button down for longer than 4 seconds until the violet LED
light up.
2. Clear “paired connection” entry in internal bluetooth interface
After activating the Reader with the Scan button the “paired connection” entry in Bluetooth
interface is cleared by holding the Reset button down for longer than 4 seconds until the violet LED
light up. See also Fig. 6: Reset Time diagram.
Scan - button
Reset - button
Reader
ON
OFF
Scan
Button
ON
OFF
Reset
Button
ON
OFF
Clear
“paired connection”
Longer than 4 sec
Reader
activation
Reader
ON
OFF
Scan
Button
ON
OFF
Reset
Button
ON
OFF
Reset
“Bluetooth parameters”
Longer than 4 sec
Longer than 4 sec
Reader
activation
LED
Status
LED
Status