OBID i-
scan
®
Installation
ID ISC.MR100-A / PR100-A
FEIG ELECTRONIC GmbH
Page 27 of 39
M10202-3de-ID-B.doc
E N
G
L I S H
A serial data cable with integrated power connection is available for the Reader.
(see
13.1.1.Serial data cable ID CAB.RS-A
Feig Article No.
Part No.
1690.000.00
ID CAB.RS-A
Table 3: Serial data cable
9.4. Supply voltage
Connect the 12 V DC supply voltage to terminal X2 on the circuit board.
Note:
Reversing the polarity of the supply voltage may destroy the device.
Terminal
Name
Description
X2 / Pin 9
+12V
+ 12 V DC – supply voltage
X2 / Pin 7
AGND
Ground – supply voltage
Table 4: Connecting the supply voltage
Power supply recommendations :
To take full advantage of the Reader module performance, you must use a sufficiently regulated
and noise-free power supply. Preferred is a linear power supply with 12V DC / 580 mA. When us-
ing a switching power supply, be sure that its internal switching frequency is less than 300 kHz.
(see:
Feig Article No.
Part No.
1688.000.00
ID NET.12VDC
Table 5: Recommended power supply
Note:
The power supply is supplied with a DC plug 2.5mm x 5.5mm. This is compatible with the
serial data cable ID CAB.RS-A.