Safety Instructions / Warning - Read before start-up ! 

  The device may only be used for the purpose intended by the manufacturer. 

  The operation manual should be kept readily available at all times for each user. 

  Unauthorized changes and the use of spare parts and additional devices which have not been 

sold  or  recommended  by  the  manufacturer  may  cause  fire,  electric  shocks  or  injuries.  Such 
unauthorized measures shall exclude the manufacturer from any liability. 

  The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid 

for the device. The manufacturer shall  not be held legally responsible for inaccuracies, errors, 
or  omissions  in  the  manual  or  automatically  set  parameters  for  a  device  or    for  an  incorrect 
application of a device. 

  Repairs may only be undertaken by the manufacturer. 

  Installation,  operation,  and  maintenance  procedures  should  only  be  carried  out  by  qualified 

personnel. 

  Use of the device and its installation must be in accordance with national legal requirements 

and local electrical codes . 

  When working on devices the valid safety regulations must be observed. 

  Before touching the device, the power supply must always be interrupted. Make sure that the 

device is without voltage by measuring. The fading of an operation control (LED) is no indicator 
for an interrupted power supply or the device being out of voltage! 

  Special advice for wearers of cardiac pacemakers: 

Although this device doesn't exceed the valid limits for electromagnetic fields you should keep 
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in 
the immediate proximity of the device’s antenna for any length of time. 

 

Содержание OBID i-scan ID ISC.M02.M8-B

Страница 1: ...INSTALLATION MANUAL final public B 2013 02 18 M90402 1e ID B ID ISC M02 M8 B English...

Страница 2: ...r useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments an...

Страница 3: ...eader Module 5 2 1 Performance Characteristics 5 2 2 Available module 5 3 Installation and wiring 6 3 1 Dimensions 6 3 2 Wiring 7 3 2 1 Supply voltage 7 3 2 2 RS232 LVTTL Interface 3 3V 8 3 2 3 Connec...

Страница 4: ...atically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should only be car...

Страница 5: ...nsponders so called Smart Labels with an operating frequency of 13 56 MHz according to the ISO15693 standard It is suitable for any application in which short read ranges and small reader dimensions a...

Страница 6: ...15 M90402 1e ID B 3 Installation and wiring 3 1 Dimensions Fig 1 shows the dimensions of the ID ISC M02 M8 B Reader Module in mm 5 0 3 65 0 3 80 0 3 5 0 3 45 0 3 50 0 3 16 5 0 3 4 0 3 X9 4 2 0 1 2 5 0...

Страница 7: ...of the multipoint connector X9 Note A wrong polarity of the DC voltage will destroy the reader 3 2 1 Supply voltage The reader ID ISC M02 M8 B has to supplied by a limited power supply e g NEC Class...

Страница 8: ...L interface should be kept as short as possible and must in any case not exceed 1 m The transmission parameters for the interface can be software configured Table 3 shows the standard parameters for t...

Страница 9: ...ould not increase a maximum length of 50cm 24inch The input impedance for the antenna must be calibrated to a value of 50 3 3 A not correct tuned antenna can destroy the reader The optimum working qua...

Страница 10: ...materials can have a diameter of 6mm Non conductive materials can have a diameter of up to 10mm The mounting orientation of the reader module is arbitrary The component side on the top is the preferre...

Страница 11: ...y is used 3 3 4 EMC effects from magnetic fields Since in this type of RFID Technology the communication between the reader and transponder takes place by modulation of a magnetic field alternating ma...

Страница 12: ...e MTA 100 AMP Electrical Data Supply voltage 24V DC 10 Current draw max 100mA Power consumption max 2 Watt Operating frequency 13 56 MHz Transmitting power 200mW 1dB Antenna connection up to 8 externa...

Страница 13: ...NIC GmbH Page 13 of 15 M90402 1e ID B Ambient Conditions Temperature range Operation Storage 20 C to 70 C 4 F to 158 F 40 C to 85 C 40 F to 185 F Humidity 5 95 non condensing Applicable Norms Radio ap...

Страница 14: ...OBID i scan HF Installation ID ISC M02 M8 B FEIG ELECTRONIC GmbH Page 14 of 15 M90402 1e ID B 5 Radio Approvals 5 1 Europe CE...

Страница 15: ...age 15 of 15 M90402 1e ID B When used according to regulation this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R TTE Guideline 1999 E6 da...

Отзывы: