Page 2 of 15 

M90402-1e-ID-B 

 

Note 

 Copyright 2009 

– 2013 by 

FEIG ELECTRONIC GmbH 
Lange Strasse 4 
D-35781 Weilburg-Waldhausen 
Tel.: +49 6471 3109-0 

http://www.feig.de

 

With the edition of this document, all previous editions become void. Indications made in this manual may be 

changed without previous notice. 

Copying of this document, and giving it to others and the use or communication of the contents thereof are 

forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved 

in the event of the grant of a patent or the registration of a utility model or design. 

Composition of the information in this document has been done to the best of our knowledge. FEIG 

ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this 

manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, 

despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. 

The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC 

GmbH does not give any guarantee promise for perfect function in cross environments and does not give 

any guaranty for the functionality of the complete system which incorporates the subject of this document. 

FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed 

with components and testing methods for a level of reliability suitable for use in or in connection with surgical 

implants or as critical components in any life support systems whose failure to perform can reasonably be 

expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application 

designer must take reasonably prudent steps to protect against system failures. 

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-

ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does 

not convey any license under its patent rights nor the rights of others.  

OBID

®

 and OBID i-

scan

®

 is a registered trademark of FEIG ELECTRONIC GmbH. 

All brand names, trademarks or logos are property of their respective owners. 

 

 

Содержание OBID i-scan ID ISC.M02.M8-B

Страница 1: ...INSTALLATION MANUAL final public B 2013 02 18 M90402 1e ID B ID ISC M02 M8 B English...

Страница 2: ...r useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments an...

Страница 3: ...eader Module 5 2 1 Performance Characteristics 5 2 2 Available module 5 3 Installation and wiring 6 3 1 Dimensions 6 3 2 Wiring 7 3 2 1 Supply voltage 7 3 2 2 RS232 LVTTL Interface 3 3V 8 3 2 3 Connec...

Страница 4: ...atically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should only be car...

Страница 5: ...nsponders so called Smart Labels with an operating frequency of 13 56 MHz according to the ISO15693 standard It is suitable for any application in which short read ranges and small reader dimensions a...

Страница 6: ...15 M90402 1e ID B 3 Installation and wiring 3 1 Dimensions Fig 1 shows the dimensions of the ID ISC M02 M8 B Reader Module in mm 5 0 3 65 0 3 80 0 3 5 0 3 45 0 3 50 0 3 16 5 0 3 4 0 3 X9 4 2 0 1 2 5 0...

Страница 7: ...of the multipoint connector X9 Note A wrong polarity of the DC voltage will destroy the reader 3 2 1 Supply voltage The reader ID ISC M02 M8 B has to supplied by a limited power supply e g NEC Class...

Страница 8: ...L interface should be kept as short as possible and must in any case not exceed 1 m The transmission parameters for the interface can be software configured Table 3 shows the standard parameters for t...

Страница 9: ...ould not increase a maximum length of 50cm 24inch The input impedance for the antenna must be calibrated to a value of 50 3 3 A not correct tuned antenna can destroy the reader The optimum working qua...

Страница 10: ...materials can have a diameter of 6mm Non conductive materials can have a diameter of up to 10mm The mounting orientation of the reader module is arbitrary The component side on the top is the preferre...

Страница 11: ...y is used 3 3 4 EMC effects from magnetic fields Since in this type of RFID Technology the communication between the reader and transponder takes place by modulation of a magnetic field alternating ma...

Страница 12: ...e MTA 100 AMP Electrical Data Supply voltage 24V DC 10 Current draw max 100mA Power consumption max 2 Watt Operating frequency 13 56 MHz Transmitting power 200mW 1dB Antenna connection up to 8 externa...

Страница 13: ...NIC GmbH Page 13 of 15 M90402 1e ID B Ambient Conditions Temperature range Operation Storage 20 C to 70 C 4 F to 158 F 40 C to 85 C 40 F to 185 F Humidity 5 95 non condensing Applicable Norms Radio ap...

Страница 14: ...OBID i scan HF Installation ID ISC M02 M8 B FEIG ELECTRONIC GmbH Page 14 of 15 M90402 1e ID B 5 Radio Approvals 5 1 Europe CE...

Страница 15: ...age 15 of 15 M90402 1e ID B When used according to regulation this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R TTE Guideline 1999 E6 da...