OBID i-scan
®
Installation
ID ISC.LRU1000
FEIG ELECTRONIC GmbH
Page 49 of 52
M41200-2de-ID-B.doc
E N G L I S H
4.1.1.1 Address assignment of RS485/RS422 for bus operation
For bus operation the Reader can be assigned the required bus address via software.
The address is assigned by the host computer. The software is used to assign addresses “0”
through “254” to the Reader.
Note:
Since all Readers are factory set with address „0“, they must be connected and configured
one after the other.
4.1.2 Network connection - LAN
The prerequisite for using TCP/IP protocol is that each device has a unique address on the
network. All Readers have a factory set IP address.
The Readers must be connected and configured one after the other.
Tabelle 3-1 shows the standard configuration of the network connection.
Network
Address
IP address
192.168.10.10
Subnet mask
255.255.255.0
Port
10001
Table 4-4: Standard configuration of the network connection