Mounting Instructions ID ISC.ANT.PS-A, ID ISC.ANT.T-A
FEIG ELECTRONIC GmbH
Page 21 of 28
E N G L I S H
Remove the circuit board from the housing before attaching the coaxial cable. Then feed the cable
through the cable fittings and fasten to the SMA sockets. Then mount the circuit board in the
housing and fasten the cable –glands.
Table 2 : Board socket functions
Terminal
ID ISC.ANT.PS-A
ID ISC.ANT.T-A
X1
Connects base antenna 1 or
complementary antenna 1
Connects basic antenna
X2
Connects base antenna 2 or
complementary antenna 2
Not used
X3
Connector cable from Reader
Connector cable from Reader
Caution: Maximum tightening torque for the SMA plugs is 0.45 Nm
The ID ISC.ANT.PS-A and ID ISC.ANT.T-A are connected directly to the Reader (Terminal X1)
and the circuit board (Terminal X3) using the connector cable supplied.
The antenna cables are connected to the antennas as shown in Tabelle 1 and the wiring diagrams
Two ring cores are supplied with the ID ISC.LRxxxx Reader for suppressing any possible noise.
These should be installed in the antenna connector cable for the power splitter or transformer. To
do this feed Cable 4 through the core so that the cable is located as close as possible to the core.
Figure 8: Wiring diagram for Reader with transformer and basic antenna
Figure 9: Wiring diagram: One Reader and two basic antennas or two complementary antennas
Reader
ID ISC.ANT.T
ID ISC.ANTx00/x00-A
ID ISC.ANT.PS
ID ISC.ANTx00/x00-x
ID ISC.ANTx00/x00-x
Reader