OBID
®
classic-pro
Installation
ID CPR50.10-E/-RE
FEIG ELECTRONIC GmbH
Page 30 of 39
M90701-1de-ID-B-FCC.doc
E N G L I S H
8.1.2. Connection X3 for Power supply and I/O Module
If there doesn’t exist a PoE power supply the connector X3 can be used for providing the DC volt-
age at the ID CPR50.10-E. Se
e: 8.1.4. Connection with External Powered Supply
Additionally the connector X3 on the ID CPR50.10.-E can be used for the connection of the exter-
nal I/O-Module ID CPR.I/O-A. See
: 8.1.5. Connections of the extension IO-Board (ID CPR.I/O-A)
Optionally an internal relay on the ID CPR50.10.-RE can be used.
X3
Signal
Description
ID CPR50.10-E
Description
ID CPR50.10-RE
1
VIN-EXT+ *
External DC +
External DC +
2
GND-EXT- *
External DC -
External DC -
3
TxD
Transmit Signal for ID CPR.I/O-A
internal Relay COM
4
RxD
Receive Signal for ID CPR.I/O-A
internal Relay NO
5
VCC
DC +Out put for ID CPR.I/O-A
-
6
GND-D
DC – Output for ID CPR.I/O-A
-
* The power supply via an external power supply is not necessary if the reader is powered
via PoE power supply. In that case the connection VIN-EXT+ and GND-EXT- are not used.