NOTE:
The lead-in wire should not be laid directly parallel to other power supply- and low voltage
wires.
4.3 Relay (ID CPR.02.10-B)
The device is equipped with an relay (normally open contact). The connection is executed via the
connectors [NO] and [COM].
4.4 Digital inputs
The digital inputs [IN1], [IN2] and ([IN3]) can only be connected to "intern GND" (see Fig. 8).
Any connection to external voltage might damage the unit!
Fig. 8 connection of the digital inputs
4.5 RS232 Interface (ID CPR.02.10-AD)
Readers with RS232 interface have to be connected to the host according to Fig. 9.
Fig. 9 connection of the RS232-interface
Host
R/A
T/B
GND
ID CPR.02-A
RxD
TxD
GND
INx
GND