Installation Manual ID RW24.ABC-A
FEIG ELECTRONIC GmbH
Page 25 of 32
E N G L I S H
3.3 X3: Outputs (transistor)
The transistor output of terminal block X3 are designed as OPEN collector outputs. It can be oper-
ated with the non-controlled voltage PLUS against GND or with an external voltage. By using the
PLUS, the GND and a cable length, which is larger than 3 m, you have to use shielded cable. You
have to connect the shielding to PE. The outputs are designed for 24 V of DC / 30 mA.
Notes:
•
Accidental polarity inversion or overloading of the outputs leads to its destruction.
•
The outputs are only designed for switching resistive loads.
Terminal
Code
Description
1
K-SU
Collector -signal buzzer
2
E-SU
Emitter - signal buzzer
3
K-GN
Collector - LED green
4
E-GN
Emitter - LED green
5
K-RT
Collector - LED red
6
E-RT
Emitter - LED red
7
K-GE
Collector - LED yellow
8
E-GE
Emitter - LED yellow
9
PLUS
Power supply for outputs, 24 V DC non-
controlled
10
GND
GND for outputs
Conection example: