background image

IDENTIFICATION 

ID MAX.U500i 

Safety Instructions 

 

 

 

Page 4 of 4 

 

 

NOTE: 

 

In case of power down during activated Teach-In Mode all temporarily stored authorizations are 

lost and have to be read again. 

 

In case of power down during deactivation of the Teach-In Mode (after pressing the push button 

T1 twice within short time the second time) all authorizations stored in the reader may be lost. 

A stable power supply must be ensured! 

 

Please note that in some vehicles RFID transponders may already be installed by the 

manufacturer or other system provider. These transponders could also be detected by the reader 

in Teach-In Mode. 

STEP 5 

Close the housing of the ID MAX.U500i and tighten the two hex screws. 

STEP 6 

If there is an authorized transponder in the antenna field, the traffic light LED lights up green and the relay or 
digital input is switched. If a transponder has no access authorization, the traffic light LED does not light up 
and the relay or digital input is not switched. With the “myAXXESS Manager” software, you can configure 
your own settings for the traffic light function. 
For further information, please refer to the detailed installation manual M81211-xe-ID-B or the video tutorial. 
Both are available in the download area of FEIG. 
You can use the FEIG software „myAXXESS Manager“to manage access authorizations. This and related 
information is available in the download are of FEIG (access data see page 1). 

Safety Instructions 

  

 

  The device may only be used for the intended purpose designed by the manufacturer. 

  The manual must be read thoroughly and kept safe and accessible for all users. 

  Unauthorized changes and the use of spare parts and additional devices, which have not been sold or 

recommended by the manufacturer, may cause fire, electric shocks or injuries. Such unauthorized 
measures shall exclude any liability by the manufacturer. 

  The liability prescriptions by the manufacturer in the issue valid at the time of purchase are valid for the 

device. The manufacturer shall not be held legally responsible for inaccuracies, errors or omissions in 
the manual or automatically set parameters for a device or for an incorrect application of a device. 

  Repairs may only be executed by the manufacturer. 

  Installation, operation and maintenance procedures should only be carried out by qualified personnel. 

  Use of the device and its installation must be in accordance with national legal requirements and local 

electrical codes. 

  When working on devices the valid safety regulations must be observed. 

  Special advice for carriers of cardiac pacemakers: 

Although this device doesn’t exceed the valid limits for electromagnetic fields, you should keep a 
minimum distance of 25 cm between the device or the antenna and your cardiac pacemaker. 

Отзывы: