background image

IDENTIFICATION Installation 

ID 

ISC.M02.M8

 

FEIG ELECTRONIC GmbH 

Page 15 of 16 

M02M8-IM-e_02.doc

 

5.2  1.2. USA (FCC) and Canada (IC)  

 

Product name: 

ID ISC.M02.M8 

FCC ID: 

IC: 

PJMM02M8 

6633A-M02M8

 

Notice for USA 

and Canada 

This device complies with Part 15 of the FCC Rules and with 
RSS-210 of Industry Canada. 
Operation is subject to the following two conditions.  
(1) this device may not cause harmful interference, and  
(2) this device must accept any interference received,  
including interference that may cause undesired operation. 
Unauthorized modifications may void the authority granted under Federal 
communications Commission Rules permitting the operation of this device. 
This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at 
his own expense. 
 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux 
appareils radio exempts de licence. L'exploitation est autorisée aux deux condi-
tions suivantes :  
(1) l'appareil ne doit pas produire de brouillage, et  
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, 
même si le brouillage est susceptible d'en compromettre le fonctionnement.

 

Warning: Changes or modification made to this equipment not expressly approved by 
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.   
 

 

Installation with FCC / IC Approval: 

The reader module was tested according to the standard FCC - Title 47 CFR Part 15 §207, $209 
and §225 and the ISED standard RSS  210 Issue 10 and RSS Gen Issue 5 . The module is con-
form to the listed limits in the standards. 

In normal operation the RF exposure is far below the limits of OET Bulletin 65. 

This module is approved for installation into fixed and/or mobile host platforms and must not be co-
located or operating in conjunction with any other antenna or transmitter except in accordance with 
FCC/ISED multi-transmitter guidelines. End users must be provided with transmitter operating 
conditions for satisfying RF Exposure compliance. 

The manufacturer is obliged to include a notice "Contains FCC ID: PJMM02M8 an IC: 6633A-
M02M8" at the user manual and on the product label.  

Содержание ID ISC.M02.M8

Страница 1: ...INSTALLATION MANUAL final public B 2020 06 03 M02M8 IM e_02 doc ID ISC M02 M8...

Страница 2: ...re always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect functio...

Страница 3: ...Characteristics 5 2 2 Available module 5 2 3 Available Accessories 5 3 Installation and wiring 6 3 1 Dimensions 6 3 2 Wiring 7 3 2 1 Supply voltage 7 3 2 2 RS232 LVTTL Interface 3 3V 8 3 2 3 Connecti...

Страница 4: ...tallation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its installation must be in accordance with national legal requirements and local...

Страница 5: ...uitable for any application in which short read ranges and small reader dimensions are required The module has an integrated antenna multiplexer Up to 8 external antennas can be connected 2 2 Availabl...

Страница 6: ...16 M02M8 IM e_02 doc 3 Installation and wiring 3 1 Dimensions Fig 1 shows the dimensions of the ID ISC M02 M8 Reader Module in mm 5 0 3 65 0 3 80 0 3 5 0 3 45 0 3 50 0 3 16 5 0 3 4 0 3 X9 4 2 0 1 2 5...

Страница 7: ...t of the multipoint connector X9 Note A wrong polarity of the DC voltage will destroy the reader 3 2 1 Supply voltage The reader ID ISC M02 M8 has to supplied by a limited power supply e g NEC Class 2...

Страница 8: ...TL interface should be kept as short as possible and must in any case not exceed 1 m The transmission parameters for the interface can be software configured Table 3 shows the standard parameters for...

Страница 9: ...be no longer than 1 m The use of other cable length are possible after consulting the manufacturer The input impedance for the antenna must be calibrated to a value of 50 3 3 A not correct tuned ante...

Страница 10: ...materials can have a diameter of 6mm Non conductive materials can have a diameter of up to 10mm The mounting orientation of the reader module is arbitrary The component side on the top is the preferr...

Страница 11: ...ly is used 3 3 4 EMC effects from magnetic fields Since in this type of RFID Technology the communication between the reader and transponder takes place by modulation of a magnetic field alternating m...

Страница 12: ...pe MTA 100 AMP Electrical Data Supply voltage 24V DC 10 Current draw max 100mA Power consumption max 2 Watt Operating frequency 13 56 MHz Transmitting power 200mW 1dB Antenna connection up to 8 extern...

Страница 13: ...Temperature range Operation Storage 20 C to 70 C 4 F to 158 F 40 C to 85 C 40 F to 185 F Humidity 5 95 non condensing Applicable Norms Radio approval Europa EN 300 330 USA FCC 47 CFR Part 15 Kanada I...

Страница 14: ...ELECTRONIC GmbH declares that the radio equipment type ID CPR60 is in com pliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet add...

Страница 15: ...which case the user will be required to correct the interference at his own expense Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exp...

Страница 16: ...be set to normal operation ScanMode The Scan mode is switched with on by SW command Transparent Command ISO 14443A ReqA HEX 02 00 0A FF 00 30 02 01 The manufacturer is obliged to test the terminal eq...