Digitale Eingänge 

Digital Inputs 

Der Leser verfügt über 5 digitale Eingänge. Diese 
sind für einen maximale Spannung von 10 V DC 
und einen maximalen Strom von 20 mA 
ausgelegt. Mit einem zusätzlichen externen 
Vorwiderstand kann eine Spannung von bis zu 24 
V DC angelegt werden. Die digitalen Eingänge 
werden an Klemme X5 des Lesers 
angeschlossen. 

The reader is equipped with 5 digital inputs. The 
inputs are designed for a maximum voltage of 10 
V DC and a maximum current of 20 mA. In 
combination with an additional external series 
resistor a maximum voltage of 24 V DC can be 
connected. The digital inputs are connected to 
Terminal X5 of the reader.

 

 

X5 

 

 

 

 

External voltage U

ext

 

Required external series resistor R

ext

 

5 V ... 10 V 

--- 

11 V ... 15 V 

270 

 

16 V ... 20 V 

560 

 

21 V ... 24 V 

820 

 

 

 

 

Содержание ID ISC.LRU3500

Страница 1: ...e der Ethernet Schnittstelle Thank you for deciding to purchase the ID ISC LRU3x00 EU FCC The ID ISC LRU3x00 EU FCC is a device for contactless data exchange with common Transponder according to EPC C...

Страница 2: ...Class 2 LPS power supply according IEC EN 60950 only Terminal Abbreviation Description X1 Pin 1 VDC Vcc supply voltage 24 V DC 5 X1 Pin 2 GND Ground supply voltage Serielle Schnittstellen Serial Inte...

Страница 3: ...C angelegt werden Die digitalen Eing nge werden an Klemme X5 des Lesers angeschlossen The reader is equipped with 5 digital inputs The inputs are designed for a maximum voltage of 10 V DC and a maximu...

Страница 4: ...angeschlossen The reader is equipped with 2 digital outputs The outputs are designed for a maximum voltage of 24 V DC and a maximum current of 30 mA The digital outputs are connected to Terminal X5 o...

Страница 5: ...voltage of 24 V DC and a maximum current of 2 A The switching current should not exceed 1 A The relay outputs are connected to Terminal X5 of the reader X5 Eine Verpolung oder berlastung des Ausgangs...

Страница 6: ...Plan 902 MHz 928 MHz FCC 47 CFR Part 15 247 Antennenanschl sse antenna connections 4 x SMA socket 50 RF Sendeleistung RF transmitting power LRU3000 LRU3500 300 mW 2 W configurable 300 mW 4 W configur...

Страница 7: ...correct the interference at his own expense Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditi...

Страница 8: ...m separation of 23 cm 9 inch between antenna and the human body must be maintained The operation manual should be conveniently kept available at all times for each user Unauthorized changes and the us...

Отзывы: