4.3.5.1. Address assignment of RS485 for bus operation
For bus operation the Reader can be assigned the required bus address via software.
The address is assigned by the host computer. The software is used to assign addresses “0”
through “254” to the Reader.
A potential termination of the interface bus can be configured by the software as well.
NOTE:
Since all Readers are factory set with address „0“, they must be connected and configured
one after the other.
4.3.6. Data-Clock Interface on connector X5
The connection of the data-clock interface take place via the digital Outputs OUT1 and OUT2 at
connector X5. The wire for the clock needs to be connected to connector OUT1-C, the wire for the
data needs to be connected to connector OUT2-C.
Figure 11: Data-Clock Interface on connector X5
NOTE:
Clock / Data-0