Installation
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 13 of 32
M21016-3e-ID-B
4.3. Interfaces
4.3.1. Ethernet Interface on connector X2
The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on
X2 and has an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps
or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address.
Table 8: Standard factory configuration of the Ethernet connection
Network
Address
IP-Adresse
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
OFF
NOTE:
The reader is equipped with a DHCP ready Ethernet Interface.
4.3.2. USB Interface on connector X3
The USB socket on the board is terminal X3. The pinout is standardized. The data rate is reduced
to 12 Mbit (USB full speed). A standard USB-cable can be used.
Figure 6: USB-Interface for host communication
NOTE:
The length of the USB-cable can have a max. of 5m (20 inch). It is not allowed to use longer
cables.
4.3.3. USB Interface on connector X4 (WLAN)