IDENTIFICATION
Installation
ID ISC.LRU1002
FEIG ELECTRONIC GmbH
Page 13 of 32
M61110-2e-ID-B.docx
4.3.2.3. Storing the reader configuration on a USB flash drive
While connecting the USB flash drive on a running reader, the reader will store the configuration as
a editable and readable CSV-file (CONFIG.INI) on the USB flash drive. This file will be stored in
the main directory for easy coping of the configuration (
4.3.2.4. Copy the configuration onto the
). Additionally the same file will be stored in the subdirectory named after
the according Device-ID (see type plate of the reader). Thereby it is possible to store several con-
figuration files on the same USB flash drive.
All not locked configuration pages (CFG pages) including the interface parameter will be copied
from the reader onto the USB flash drive. Password protected configuration pages will not be cop-
ied.
After plug-in of the USB flash drive the green and red status LED are permanently lit as long as the
USB flash drive is actively used by the reader. When the USB actions are completed successfully,
the red LED is switched off and the green LED starts flashing. The USB flash drive can be re-
moved after the red LED is switched off. If the USB actions failed the red status LED starts flashing
until the USB flash drive is removed.
Note
:
If there exists already a configuration file CONFIG.INI on the main directory of the USB flash
drive, the old file will be overwritten by the new configuration file.
Configuration pages which are protected by a password (see CFG0) will be not stored on
the USB flash drive. No error message will appear.
After connecting the USB flash drive on the reader USB port, the reader LEDs should be
observed.
The USB flash drive shall only be removed from the reader if the USB actions have been
completed and the flash drive is not in use anymore.
4.3.2.4. Copy the configuration onto the reader (Config-Cloning)
In order to connecting the USB flash drive on the reader USB port and copy the configuration from
the USB flash drive onto the reader, it is necessary to switch off the reader before plug-in the USB
flash drive. After switching on the reader the boot process will look for a connected USB flash drive
and will copy the existing configuration file onto the reader.
It must be ensured that no configuration page (CFG page) is locked inside the reader. If configura-
tion pages are locked the configuration file will not be copied onto the reader. If single configuration
parameters in the configuration file were out of range and invalid the configuration file will not be
copied onto the reader as well.
After the copy process has been finished the green LED will start flashing and the red LED goes
off. After the red LED goes off the USB flash drive can be disconnected. If the USB actions failed
the red status LED starts flashing until the USB flash drive is removed.