IDENTIFICATION
Installation
ID ISC.LRU1002
FEIG ELECTRONIC GmbH
Page 12 of 32
M61110-2e-ID-B.docx
4.3.2.1. USB-Stick Service-Functions
Via an optionally available USB On-The-Go adapter cable, the interface can be converted to a
USB host interface. The adapter cable allows the connection of a USB memory stick to the reader.
By means of the USB stick various service functions can be carried out e.g. the read-out of log and
service files and uploading of a configuration file.
Figure 6: USB On-The-Go adapter cable
4.3.2.2. Reading of Log and Service Data
After plug-in of the USB flash drive on the running ID ISC.LRU1002 the reader will generate a sub-
directory on the root directory of the USB flash drive. The name of the subdirectory is equal to the
Device-ID of the connected reader (see type plate of the reader). Within this subdirectory the
reader stores device information like firmware version and IP-address in the file INFO.LOG. If there
exist already such a file for the same reader the file will be updated with the information and the
current date and time.
Additionally the files ACTION.LOG and SERVICE.LOG will be generated and stored for service
purposes on the USB flash drive. The meaning of the CONFIG.INI will be described in the next
chapter.
After plug-in of the USB flash drive the green and red status LED of the ID ISC.LRU1002 are per-
manently lit as long as the USB flash drive is actively used by the reader. When the USB actions
are completed successfully, the red LED is switched off and the green LED starts flashing. The
USB flash drive can be removed after the red LED is switched off. If the USB actions failed the red
status LED starts flashing until the USB flash drive is removed.
NOTE:
After plug-in of the USB flash drive the status LEDs of the reader shall be monitored.
The USB flash drive shall only be removed from the reader if the USB actions have been
completed and the flash drive is not in use anymore.