7.2.2 Configuration and Test in ISO-Host or Buffered Read
Step
Action
Note
1
Select „Configuration“
2
Host Interface
Set RS 485 to “False” and
„Enable Termination
Resistors“
The RS232/485 Settings
should be set to:
Busaddress=0,
Baudrate=38400 baud,
Parity = even ,
Number of Databits = 8,
Number of Stopbits = 1
3
Confirm with „Apply“
4
Peripheral Devices
Gate People Counter
Set Antenna Type
“Standard”
Mode
Enable GPC to
„New Generation”
5
Confirm with „Apply“
6
Peripheral Device
LED Controller:
Setting Time:
„Setting Time“ set the dura-
tion time for the alarm.
(10 means 1 second)
(e.g. 10 x 100ms)
Set the colour for the
LED´s
Assign
LED Bus Address 11 to
antenna 1.
LED Bus Address 12 to
antenna 2.