ORIGINAL INSTRUCTIONS
• Loosen the retaining screw of the cover using a Philips screwdriver.
WARNING! Do not fully remove this screw.
• Fold the saw blade guard (9) upwards until the saw blade guard (9) is above the flange screw.
• With one hand insert the Allen key in the flange screw.
• Hold the Allen key and slowly close the saw blade guard (9) until it touches the Allen key.
• Firmly press the saw shaft lock (22) and slowly rotate the flange screw in clockwise direction. The saw
shaft lock (22) engages after no more than one rotation.
• Now, using a little more force, slacken the flange screw in the clockwise direction.
• Turn the flange screw right out and remove the outer flange.
• Take the blade of the inner flange (31) and pull out downwards.
• Carefully clean the flange screw, outer flange and inner flange (31).
• Fit and fasten the new saw blade in reverse order.
• Important! The cutting angle of the teeth, in other words the direction of rotation of the saw blade must
coincide with the direction of the arrow on the housing.
• Before continuing your work, make sure that all safety de
y
vices are in good working condition.
• Important! Every time that you change the saw blade, check to see that it spins freely in the table
insert (19) in both perpendicular and 45° angle settings.
• Important! The work to change and align the saw blade must be carried out correctly.
Transport
• Tighten the handle (34) to lock the rotary table.
• Press the machine head (4) downwards and secure with the locking bolt (3).
• Fix the saw’s drag function with the locking screw for drag guide (25) in rear position.
• Carry the equipment by the fixed saw table (15).
• When reassembling the equipment proceed as described under section 7.