Use of AC Power
Connect the ground bolt.
Start the engine in accordance with the “Start the Engine” requirements.
Make sure the connected device is turned off, then connect the device to the generator.
When the LCD is on, turn on the connected device.
BE CAUTIOUS
If the connected device is not turned off before you start the generator, it will start suddenly,
resulting in personal injury.
LCD and Oil alert indicator
The LCD lights up after you start the generator.
If the generator is overloading or the connected device is internally faulty, the LCD displays
“Overload”, and there will be no power output. You must shut the generator off to stop the
generator.
During the normal operation of the generator, the LCD will display the current output status in real
time.
If the generator is overloading or the connected device is internally faulty, the LCD will display “0”
instead of the status of the generator on Voltage, Current or Frequency, and the Power column will
display “OVER”.
If the LCD displays “Overload”, the generator will not stop automatically at this time. Please unplug
the connected device from the generator, turn off the device, check the device and the connecting
cable, confirm the cause of the overload. After you find out the cause of the overload and confirm
that the problem has been resolved, press the Reset Button on the control panel. After 3 seconds
the LCD turns normal and the generator will start operating normally.
If you press the Reset Button, wait 3 seconds and the LCD doesn’t turn normal, please turn off the
generator and contact the authorized dealer.
If the oil alarm indicator is on, the engine will automatically shut down. Please check whether the oil
should be added.