ORIGIINAL INSTRUCTIONS
9
burner head. Air also passes through the nozzle where it mixes with the fuel and is sprayed into the
combustion chamber in a fine mist.
Quick-Fire Ignition:
A transformer sends high voltage to a two pronged spark plug. The spark
ignition the fuel/air mixture as it is sprayed into the combustion chamber.
Air System:
A fan is turned by the heavy duty motor, which forces air around and into the
combustion chamber, where it is super-heated and forced out the front of the chamber.
Temperature Limit Control:
This heater is equipped with a temperature limit control designed to
turn the heater off should the internal temperature rise to an unsafe level, if this device activates
and turns your heater off, it may require service.
Once the temperature falls below the reset temperature, you will be able to start your heater.
Electrical System Protection:
The heaters’ electrical system is protected by a circuit breaker
that protects the system components from damage. If the heater fails, check the fuse first,
and replace if necessary
Flame Sensor:
The heater uses a photocell to see the flame in the combustion chamber. Should
the flame extinguish, the sensor will stop electrical current and the heater will shut off.
FUELING THE HEATER
NEVER FILL FUEL TANK INDOORS. ALWAYS FILL FUEL TANK OUTDOORS. BE
SURE THAT THE HEATER IS ON LEVEL GROUND WHEN FUELING,AND NEVER OVERFILL
FUEL TANK.
NEVER REFUEL THIS HEATER WHILE IT IS HOT OR OPERATING,FIRE OR
EXPLOSION COULD RESULT.
It is always a good idea to fire the heater outdoors for the first time. This will allow any oils used in
the manufacturing process to be burned off in a safe environment. This is initial burn should last
at least 10minutes.
7. VENTILATION
Risk of indoor air pollution. Use heater only in well ventilated areas.
Always provide a fresh air opening in the heated space of at least three square feet(2800 sq.cm) for
each 29KW/hr of heater output. Provide a larger opening if more heater will require.
-a two-car garage door raised 15.24cm (6 inches)
-a single-car garage door raised 22.86cm (9 inches)
-TWO, 76.2cm (30 inches) windows raised 38.1cm(15inches)
TO START THE HEATER
1) Fill the tank with Diesel (1-K Kerosene) until fuel gauge point to “F”
2) Be sure fuel cap is secure.
3) Plug power cord into the local correct plug. Grounded extension cord and plug
extension cord into three prong 220-240V grounded outlet. The extension cord should