It has 64 positions for saving user-defined waveform. Waveform Length of
each one is 8192 * 14 bits.
High frequency precision up to
10
-6
orders of magnitude.
F
ull range of 1μHz
(
0.000001Hz
)
frequency resolution.
Minimum amplitude resolution can be up to 1 mV
(
0.001V
)
.
-10V~+10V DC Offset function
(
<20MHz
)
. Resolution 1mV.
Duty cycle of each channel can be adjusted separately. Precision can be
0.1%.
Pulse wave pulse width and pulse frequency can be adjusted continuously,
the range of adjustment is 20ns-1S.
The pulse amplitude can be continuously
adjusted between 0-10V
,
adjustment accuracy of 0.001V.
Phase of two channels adjustable during 0~359.9°. Accuracy can be 0.1
°
.
Direct digital Setting covering full range of frequency without grading.
Sweep Function: It can sweep 4 properties of signals including frequency,
amplitude, offset and duty cycle. It has Linear and Logarithm two sweep types.
Sweep time can be up to 999.99S. Sweep starting point and end point can be
set arbitrarily.
It has pulse train burst output function. There has Manual Trigger, internal
CH2 Trigger, and External Trigger for your options. It can output 1~1048575
pulse trains.
Digital signal output function can output any 0~10V CMOS electric level.
VCO voltage controls parameters of signal output available (for example:
voltage controlled oscillator).
Save function: It can save 20 sets user-set parameters and can be loaded at
anytime.
100M Frequency meter function: It can measure frequency, period, pulse
width and duty cycle. Max. frequency workable is 100MHz and Min.
frequency workable is 0.01 Hz.
Counter Function: It has 2 coupling measure modes including DC coupling
and AC coupling. This design can solve inaccuracy problem of AC coupling.
All parameters can be calibrated by internal program.
Powerful arbitrary waveform edit function: Users can download arbitrary
waveform to this instrument after edit through PC program which is included
in user CD.
Powerful communicating function. All functions can be controlled by PC
Содержание FY-6800