Feel Good RK8900S Скачать руководство пользователя страница 12

19

20

1 After power on, keep pressing the on/off key at least 4s, the chair will turn on. 
    Meantime, the Bluetooth mark on the control will be lit, you can select auto or manual 
    program by menu or keys, then the body scan and massage would begin. Press the 
    on/off key 4s to turn off the power, the massage chair will stop massage and 

 

   off, the back massage machine reset at the back part, the leg-rest moves down to 
   bottom, the back moves up to top, remote control powers off after 3s to 5s.

power

2 Press this key to enter the Quick Relaxation mode, with the status showing on the 
    screen. The default working time is 8mins.

5
    massage programs, Recover, Relief, Stretch, Renew, Music sync and Calming. 
    A status display can be seen at the top of the screen.

When power on, press this key to select an automatic program. There are six auto 

3

When power on, press this button to stop all the functions. All the buttons become 

    invalid at this moment; Press on/off key to re-activate the remote control to continue 
    the massage.

6

The direction key has four buttons, up and down, left and right. In menu mode, they are 

    navigation keys which can be used to quickly select the upper or lower menu item. In 
    manual mode, the up and down key can be used to adjust the position of massage 
    machine during the shoulder height detecting and fixed point massage.

7

In ON status and under Menu mode, press it to confirm menu choice and enter next 

    menu.

  

When at the main interface, press this button to turn on the anion function, press it 

    again to turn off anion function.

MENU

Quick

relaxation

AUTO

OK

Manual control

Manual control

Manual control

M

as

sa

ge

 op

era

tio

n

M

as

sa

ge

 op

era

tio

n

Emergency Off

MENU

OK

Quick

relaxation

AUTO

Quick relaxation

Zero

Speed

Width

Intensity

4D

20 

min

Set function by pressing Menu key.

On/Off 

Menu

Confirm button 

Left 

Legrest down 

Legrest up

Auto 

Up

Right

Down

Legrest up& 

backrest down
Zero-Gravity  

Backrest

legrest down

 up& 

4. Press this button in Main interface to switch to menu interface, user can set 
    different function for massage chair. Press it in Menu interface to return to main 
    interface.

12. 

In ON status, press this key once to reach zero-gravity level one state; press this key 

      again to reach zero-gravity level two state; press the key for a third time to reach 
      sleeping mode. Press it for a fourth time, massage chair resets to upright position. 
      It works like this in circles.

8. Keep pressing this button, legrest goes up, release it, legrest stop moving. 

    Controller screen will show position adjusting

… 

when adjusting the position

 

  

of

 

massage chair

.

9. Keep pressing this button, backrest goes up, legrest goes down, release it, 

    backrest and legrest stop moving. Controller screen will show position 

    adjusting

… 

when

 

adjusting

 

the

 

position

 

of

 

massage

 

chair

.

10. Keep pressing this button, legrest goes down, release it, legrest stop moving. 

      Controller screen will show position adjusting

… 

when

 

adjusting

 

the

 

position

 

   

of

 

massage

 

chair

.

11. Keep pressing this button

,

backrest go down

,

legrest go up

,

release this button

,

   

backrest

 

and

 

legrest

 

stop

 

moving

.

When adjusting sitting position, it shows 

      seat position adjusting

… 

in

 

controller

 

screen.

Wireless

 

controller

 

connects

 

Bluetooth for

 

the

 

first

 

time

1.Turn on massage chair switch

,

controller clings to the power box upper right position after booting

  

hold

 

Menu 

OK button at same time for over 4 seconds

,

screen will show Bluetooth pairing

.

2.The Bluetooth sign will be lightened if Bluetooth connection is successful

,

the pairing is done

.

3.After pairing successfully

,

please turn off and turn on controller again

,

you can use wireless 

   controller to operate massage chair

.

4.Turn on controller next time

,

it will connect paired massage chair automatically

.

Controller reset

USB cable port

Note

:

Usually

,

the chair is set up well for you when making delivery

,

if you find it doesn't connect 

after controller booting

,

please follow the above steps

,

if the controller can't turn on or is in low 

battery

,

please charge it with the USB cable attached

.

Controller

 

reset

:

If the controller system halt

,

please find a sharp object to press the button in the reset hole

,

controller will reset

.

Содержание RK8900S

Страница 1: ...RK8900S Please read SAFETY INSTRUCTIONS carefully before using the chair User s Manual Massage Chair...

Страница 2: ...sage function in foot parts stimulate the foot reflection zone by foot roller heating function 11 12 13 Footrest can be extended and retracted within the range of 22 cm suitable for different height p...

Страница 3: ...use Insert the plug of the chair into correct and suitable power socket Make sure the plug is completely inserted into the socket to reduce short circuit or fire risk Unplug the power when not in use...

Страница 4: ...dn t be bend or cut off Don t press with hands or step on the massage heads with feet Don t put hands between the working massage heads Don t put hands or feet in the gap of mechanical parts Don t dro...

Страница 5: ...s Preparation Back seat cushion Loud speaker Left shoulder massage device Right shoulder massage device Right armrest Legrest Footrest Head pad Left armrest Castor Remote control Remote control pocket...

Страница 6: ...sembly 1 13 14 7 8 1 1 19 Shoulder device assembly 20 Back cover assembly 1 1 Mechanical components diagram Mechanical components list Explosion Diagram Preparation Mechanical components list Preparat...

Страница 7: ...table or ground in flat pay attention to prevent scratches Taking out the legrest device from the legrest carton box catching the front and back two sides of the legrest and take them out Right armres...

Страница 8: ...fixed plate and LED wire need to be plugged firmly otherwise the armrest may drop or LED light does not shine Insert the rear armrest fixed plate into the fixing hole on the chair body Remove the rub...

Страница 9: ...ion head pad onto the backrest and connect the two parts with zipper and velcro shoulder cushion Warm tips In order to get exact correct body test data for comfortable massage effect when you sit on t...

Страница 10: ...heavy thing especially can t be pressed by the chair on power cable At least 50cm in front of the leg Check surroundings When the backrest or legrest reclines or extends please pay attention to 1 Chec...

Страница 11: ...ins Regimen of TCM light comes on default working time is 20mins Stretch light comes on default working time is 20mins Rhythm massage light comes on default working time is 20mins In power on mode pre...

Страница 12: ...ce to switch to menu interface user can set different function for massage chair Press it in Menu interface to return to main interface 12 In ON status press this key once to reach zero gravity level...

Страница 13: ...nd brittle LCD screen display boot screen after 2 3 seconds it displays the main interface and enter standby mode Main interface show massage position method time current massage status etc all inform...

Страница 14: ...aterial is broken if there is damage please stop using unplug the chair and ask for repairment 2 Only plug to proper socket Warning Attention 1 Before sitting down make sure there is no things pinched...

Страница 15: ...re is no people or pet or anything within the range of backrest and legrest Make backrest and legrest restore to the normal position by controller or press ON Off key to make backrest and legrest rest...

Страница 16: ...o need to pay attention to it Turn off the power to have the massager rest for over half an hour before next turn working Connect the electricity power again Check whether the plug and socket in poor...

Страница 17: ...Name Model Input voltage Safety design AC120V 60Hz AC220V 50 60Hz AC240V 50Hz Class NW GW Packing size Power Main body 100 121 kg Armrest 14 8 19 kg Legrest footrest 31 5 35 5 kg Main body 1520 795 9...

Отзывы: