SINGLE CASE INSTALLATION (STAND ALONE UNITS)
Leveling the Case
It is important that the case is level. This will allow for proper drainage of condensate
water from evaporator coil. Once the case is placed in final location the case must be
level for proper drainage of defrost water to the condensate pump. A wrench is included
to aid in adjusting leg levelers.
Check the left-to-right level of the case along front of plastic air deflector retainer.
Check the front-to-rear level of the case along the interior ends of the case.
LEVEL CASE USING THESE SURFACES
Adjust the (4) outside leg levelers as needed to level the case in each direction.
NOTE: If necessary, use a wood or plastic shim under each leg leveler to avoid
scratching the tile floor.
Sealing Unit to The Floor
After the unit is positioned and the leg levelers are turned out, the unit needs to be
sealed to the floor for NSF approved installation.