background image

E3980 

Rev A 11/23/2021

 

 

 

INSTALLATION & OPERATIONS INSTRUCTIONS 

VRSS: Self-Contained & Remote Refrigerated Models 

VNSS: Non-Refrigerated Displays 

 

KEEP THIS MANUAL FOR FUTURE REFERENCE 

Engineering and technical data are subject to change without notice. 

FEDERAL INDUSTRIES  

 

215 Federal Ave   

 

Belleville, WI  53508 

Toll Free 1(800) 356-4206  

 

WI Phone (608) 424-3331  

Fax: (608) 424-3234 

Содержание VRSS Series

Страница 1: ...emote Refrigerated Models VNSS Non Refrigerated Displays KEEP THIS MANUAL FOR FUTURE REFERENCE Engineering and technical data are subject to change without notice FEDERAL INDUSTRIES 215 Federal Ave Be...

Страница 2: ...7 4 Installation for joined cases Lineups 12 8 Shelf installation and removal 15 8 1 Shelf brackets and supports 15 9 Electronic Temperature Control Refrigerated units only 19 10 Initial Startup Refri...

Страница 3: ...is manual covering components contain technical instructions intended only for persons qualified to perform electrical work DANGER Improper or faulty hookup of electrical components in the case can re...

Страница 4: ...n this section and throughout the manual The following signal words are used in the warning and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury...

Страница 5: ...EL GRILLE BOTTOM END CORD AND PLUG END GLASS AIR DEFLECTOR CONTROLS END GLASS TRIM AIR DEFLECTOR RETAINER AIR DEFLECTOR RETAINER BRACKET INTERIOR BACK PANEL CANOPY FRONT VALENCE AIR DISCHARGE AIR RETU...

Страница 6: ...E3980 VRSS 6 CONTROLS PRICE TAG MOLDING PRICE TAG MOLDING...

Страница 7: ...elf contained models are similar Non refrigerated units have no components in the base except power cord CONDENSER BAFFLE TOP CONDENSER BAFFLE SIDE DRAIN TRAP DRAIN HOLE FRONT OF UNIT FLEXIBLE REFRIGE...

Страница 8: ...to shipping crates cartons or if a shortage is found note this on the bill of lading all copies prior to signing If damage is discovered when the case is uncrated immediately call the delivering truc...

Страница 9: ...of case and product If this case or cases are to be located against a wall there should be at least 6 between the case and the wall to allow air circulation Failure to give adequate space may cause e...

Страница 10: ...Packaging Material Remove bubble wrap and packing material for all shelves and panel brackets etc If it is necessary to remove tape residue from plastic materials use cleaning compounds recommended in...

Страница 11: ...ng leg levelers Check the left to right level of the case along front of plastic air deflector retainer Check the front to rear level of the case along the interior ends of the case LEVEL CASE USING T...

Страница 12: ...bolt units together 2 Position the right or leftmost unit in the desired position for the lineup to start and level this case 3 Push the 2nd case next to the 1st and line them up as closely as possib...

Страница 13: ...nterior back panel s exterior back s front and rear base panel and loosen honeycomb see cleaning section for honeycomb removal material on the unfinished end to expose the holes used to bolt units tog...

Страница 14: ...he joining process loosening the glass trim on the case to slide the joining trim over the existing trim and secure with the existing fasteners Do this for both the top trim and the rear trim FRONT VI...

Страница 15: ...ll not maintain product temperature Shelves are pre installed in the factory To change shelf positions remove the shelf then shelf support then brackets Relocate the brackets to the desired shelf posi...

Страница 16: ...ighten or angle the shelves To angle the bracket be sure to have the top hook of the bracket in its slot and to pull up while rotating down to the most extreme downward position To angle the shelf fir...

Страница 17: ...the cover tilted out 2 Insert the bottom of the security cover into the lower u clip retainer by rotating the top of the assembly in toward the case and dropping the cover down into place 3 The top o...

Страница 18: ...E3980 VRSS 18 When installing the security cover panel ensure that the bottom of the panel is seated in the lower u clip and that the latch fully engages behind the upper retaining bracket...

Страница 19: ...ment menu When not in set point menu shows maximum temperature of the display probe Down Change set points when in set point adjustment menu When not in set point menu shows minimum temperature of the...

Страница 20: ...gher the number of the set point the colder the display case will run with setting 9 being the coldest and setting 1 being the warmest Once you have chosen your desired setting press the button again...

Страница 21: ...Display Description Cause Resolution P1 Air discharge temperature probe failure Probe signal is interrupted or short circuited Check to ensure probe wires and quick disconnect are secure in control Ch...

Страница 22: ...s power switch marked POWER to the on or I position 9 If the control reads OFF then press and hold the control s power button to turn it on 10 In a few moments the refrigeration system will turn on 1...

Страница 23: ...lf location Allow a minimum of 2 between top of product and bottom of next shelf up Do not overhang the front or rear of shelves with product Improper clearance in front and rear of shelf will block t...

Страница 24: ...ature before proceeding with cleaning NOTICE Remove all products from the case before proceeding with cleaning procedure NOTICE This case is not designed to be cleaned by flushing Note For major spill...

Страница 25: ...o be cleaned by flushing 1 Side and rear door glass can be cleaned with common window cleaners 2 Remove interior shelving and display deck from unit as described in the Shelving Installation and Remov...

Страница 26: ...CONDENSER COIL WILL VOID COMPRESSOR WARRANTY It is very important that the Condenser coil is cleaned monthly to ensure proper refrigeration performance and to prevent compressor failure Failure to cle...

Страница 27: ...se contact Phone 800 356 4206 and choose the Tech Support Warranty Option Email Service federalind com For Warranty Compressors please contact the Parts Department Phone 800 356 4206 and choose the Wa...

Страница 28: ...are included with it If you need replacement labels or manuals Federal Industries will provide them free of charge Contact the customer service department at Federal Industries at 800 3564206 The cust...

Страница 29: ...NEMA CORD AMPS 12 7 20 CONDENSATE REMOVAL SHIP WEIGHT PERMANENT CONNECT MAX FUSE SIZE C U HP R449A 6 720 PUMP VRSS4860S 208 240 60 1 12 5 20 NEMA 6 20P NEMA 5 20P R449A 3 4 INTEGRATED PAN 2 5 15 VRSS...

Страница 30: ...regional or national electrical standards A separate circuit for each display case is required to prevent other appliances on the same circuit from overloading the circuit and causing malfunction The...

Страница 31: ...E3980 VRSS 31 16 WIRING DIAGRAM 16 1 VRSS SELF CONTAINED 16 2 VRSS REMOTE...

Страница 32: ...E3980 VRSS 32 16 3 VNSS...

Страница 33: ...60IN 33 21288 3 1 1 COIL EVAPORATOR 72IN 33 21288 4 1 1 CONDENSING UNIT 36IN 30 21316 1 1 CONDENSING UNIT 48IN 30 21317 1 1 CONDENSING UNIT 60IN AND 72IN 30 21318 1 1 1 1 CONDENSATE HEATER 400W 120V 4...

Страница 34: ...1RW GREY 68 21331 1LG 68 21331 1RG LEFT RIGHT BLACK 68 21301 2LB 68 21301 2RB WHITE 68 21301 2LW 68 21301 2RW GREY 68 21301 2LG 68 21301 2RG LEFT RIGHT BLACK 68 21331 1LB 68 21331 1RB WHITE 68 21331 1...

Страница 35: ...LACK M21387 1B M21488 2B M21487 2B WHITE M21387 1W M21488 2W M21487 2W STAINLESS M21387 1S M21488 2S M21487 2S COLOR BRACKET NEED TWO SUPPORT SHELF BLACK M21387 1B M21488 3B M21487 3B WHITE M21387 1W...

Страница 36: ...E3980 VRSS 36 REV CHANGE RECORD APP D DATE ECN INITIAL RELEASE JTR 11 12 21 A Added security cover and additional wiring diagrams JTR 11 23 21...

Страница 37: ...be done in accordance with all applicable local regional or national standards NOTICE TO EMPLOYERS You must make sure that everyone who installs uses or services your case is thoroughly familiar with...

Страница 38: ...ity Exceeding these limits will cause poor case performance and sweating For more detailed information on control operation see the section Electronic Temperature Control in the full manual 20 PLACING...