Self-Contained Models
The self-contained models are shipped from the factory with a completely operational
refrigeration system and require no modifications or adjustments of the system upon
installation.
Remote Models (Obsolete as of 1/1/2012)
The remote models are designed to use 134A refrigerant and shipped from the factory with
the evaporator coil, expansion valve, refrigerant solenoid valve, and thermostat. The
thermostat senses interior case temperature and opens and closes the refrigerant solenoid
valve as needed to maintain proper case temperatures. The condensing unit is optionally
supplied from the factory for remote location installation.
A.
Mount condensing unit indoors as close to the remote display as practical. The
refrigeration line should be as short as possible.
B.
All refrigeration and/or electrical materials between the condensing unit and display
case are to be supplied by installing contractor.
C.
Route properly sized and designed refrigeration lines from the condensing unit to the
cabinet. Horizontal suction lines should be pitched downward towards the condensing
unit and least ½” per 10’ run to aid the oil drainage. A “P” trap must be installed in the
suction line at the foot of every riser to insure oil return. Dry nitrogen should be used to
flow through tubing while brazing refrigeration lines.
D.
Suction line must be insulated the entire length with Armaflex (or equivalent). Do not
run liquid line inside insulation with suction line.
E.
The filter drier, sight glass, and low-pressure control are not furnished with remote
display case models. The recommended low pressure setting for R134A refrigerant is
32# cut in and 0# cut-out.
F.
Leak check condensing unit, cabinet, and all connecting tubing. Cabinet and
condensing unit tubing should be checked to insure no leaks occurred during shipping
or from rough handling. Make certain all refrigeration valves are opened and evacuate
system to 500 microns. Charge the system with refrigerant type specified on the data
plates.
Содержание SNR48
Страница 29: ...Series 90 Refrigerated Bakery Page 29 WIRING DIAGRAM SELF CONTAINED WIRING DIAGRAM SNR48SC 2 SNR59SC 2...
Страница 30: ...Series 90 Refrigerated Bakery Page 30 WIRING DIAGRAM SNR77SC 2...
Страница 31: ...Series 90 Refrigerated Bakery Page 31 WIRING DIAGRAM SN48 3SC 2...
Страница 32: ...Series 90 Refrigerated Bakery Page 32 WIRING DIAGRAM SN59 3SC 2 SN77 3SC 2...
Страница 33: ...Series 90 Refrigerated Bakery Page 33 WIRING DIAGRAM SN4CD...
Страница 34: ...Series 90 Refrigerated Bakery Page 34 WIRING DIAGRAM SN6CD...
Страница 35: ...Series 90 Refrigerated Bakery Page 35 WIRING DIAGRAM SN8CD...
Страница 36: ...Series 90 Refrigerated Bakery Page 36 WIRING DIAGRAM REMOTE WIRING DIAGRAM SNR48R 2 SNR59R 2 OBSOLETE 1 1 2012...
Страница 37: ...Series 90 Refrigerated Bakery Page 37 WIRING DIAGRAM SNR77R 2 OBSOLETE1 1 2012...
Страница 38: ...Series 90 Refrigerated Bakery Page 38 WIRING DIAGRAM SN48 3R 2 OBSOLETE1 1 2012...
Страница 39: ...Series 90 Refrigerated Bakery Page 39 WIRING DIAGRAM SN59 3R 2 SN77 3R 2 OBSOLETE 1 1 2012...
Страница 40: ...Series 90 Refrigerated Bakery Page 40 WIRING DIAGRAM SN4CDR OBSOLETE 1 1 2012...
Страница 41: ...Series 90 Refrigerated Bakery Page 41 WIRING DIAGRAM SN6CDR OBSOLETE 1 1 2012...
Страница 42: ...Series 90 Refrigerated Bakery Page 42 WIRING DIAGRAM SN8CDR OBSOLETE 1 1 2012...
Страница 44: ...Series 90 Refrigerated Bakery Page 44 REV CHANGE RECORD APP D DATE ECN...