IMSS E3265
- 18 -
Initial Start-Up
After all the checks outlined in the installation section of this manual have been made, the
case is ready to be put into service. Turn on the Power at the breaker box and flip the
Power Switch and Light Switch on unit to the on position. At start up from a warm unit, it is
recommended that the temperature control is set at a warm setting, such as After the unit
has gone through several cycles, change the control to a mid-range setting, then to a
colder setting if necessary to maintain desired product temperature
NOTICE:
This refrigerated display case is designed to operate
in a maximum environment of 75 DEG. F and 55% relative
humidity. Exceeding these limits will cause poor case
performance and excessive sweating.
Placing Product into Case
-
Do not exceed 75 pounds of weight per shelf. Heavy product should be distributed
evenly across the entire shelving area.
- Determine desired shelving location before placing product in case. Product must be
removed to readjust shelf location.
-
Allow a minimum of 2” between top of product and bottom of shelf.
-
Do not overhang the front or rear of shelves with product. Improper clearance in front
and rear of shelf will block the refrigerated airflow and will cause product loss.
-
Do not block the slots along the front and rear air discharge slots. Covering these slots
will block
the refrigerated airflow and could cause product loss.
-
The display deck is removable for cleaning and can become dislodged in shipment. To
ensure proper airflow and performance of the case, make sure that the display deck is
pushed completely down.
-
Allow refrigerated models to run for at least two hours before placing pre-chilled
product into unit.
NOTICE:
CASE MUST BE STOCKED WITH PRE-CHILLED PRODUCT
ONLY.
NOTICE:
This refrigerated display case is designed to operate
in a maximum environment of 75 DEG. F and 55% relative
humidity. Exceeding these limits will cause poor case
performance and sweating of glass panels.
CLEANING INSTRUCTIONS
Acrylic Air Deflector Cleaning
NOTICE:
Clear acrylic air deflector requires special washing procedures
to prevent hazing and yellowing of material.
NEVER
USE
paper towels (wet or dry) for cleaning or drying and never use a dry towel.
NEVER USE
glass cleaner of any kind.
Lightly dust (not wipe) surface with a damp Micro Fiber towel or chamois. The surface can
then be washed using a small amount of dishwashing detergent such as Dawn or Joy and
lukewarm water. Use a Micro Fiber towel or chamois, applying only light pressure. The cloth
or chamois must be kept free of grit by frequently rinsing. Rinse surface with clear water
and dry by blotting with a damp Micro Fiber towel or chamois
.