2-4
d.
Press switch 12 (switch operation
select) to change switch operation. Continue to press
switch 12 until the “M” LED in the V-shaped display
is illuminated. The control head display now indi-
cates that switch 4 is configured with no pattern, no
SignalMaster pattern, auxiliary relay A activation,
and momentary switch operation.
e.
Press the Reset/Save switch to
save this configuration. The control head display will
indicate the last switch configured. Therefore, switch
4 LED is illuminated.
f.
To exit Level 2 Configuration,
press the Reset/Save switch a second time.
g.
Press the Reset/Save switch a
third time to exit the configuration mode. A longer
beep will sound and the Reset/Save LED will change
from flashing to steady illumination indicating the
system is ready for use.
h.
Press switch 4 and ensure that it
is now configured for momentary operation. If switch
4 is not configured for momentary operation, repeat
Change 1 as described above; if switch 4 is configured
for momentary operation, proceed to Change 2 below.
3.
Change 2—change switch 5 to eight-
second timed operation.
a.
Enter the configuration mode as
described in paragraph 2-2.A.
b.
Press switch 10 to enter Level 2
Configuration mode. A beep is heard and the Reset/
Save LED will be flashing. The two options now
available are: pressing the switch to be reconfigured,
or pressing the Reset/Save switch to save the current
configuration and exit Level 2 Configuration mode.
c.
Press switch 5. See figure 2-4.
The control head display will indicate that switch 5 is
configured with no pattern, no SignalMaster pattern,
auxiliary relay B activation, and push-on/push-off
switch operation.
d.
Press switch 12 to change switch
operation. Continue to press switch 12 until the “T”
LED in the V-shaped display is illuminated. The
control head display now indicates that switch 5 is
configured with no pattern, no SignalMaster pattern,
auxiliary relay B activation, and eight-second timed
switch operation.
e.
Press the Reset/Save switch to
save this configuration. The control head display will
indicate the last switch configured. Therefore, switch
5 LED is illuminated.
f.
To exit Level 2 Configuration,
press the Reset/Save switch a second time.
g.
Press the Reset/Save switch a
third time to exit the configuration mode. A longer
beep will sound and the Reset/Save LED will change
from flashing to steady illumination indicating the
system is ready for use.
h.
Press switch 5 and ensure that it
is now configured for eight-second timed operation.
Proceed to Change 3 below.
4.
Change 3—add auxiliary relay output
C to Mode 1.
a.
Enter the configuration mode as
described in paragraph 2-2.A.
b.
Press switch 10 to enter Level 2
Configuration mode. A beep is heard and the Reset/
Save LED will be flashing. The two options now
available are: pressing the switch to be reconfigured,
or pressing the Reset/Save switch to save the current
configuration and exit Level 2 Configuration mode.
c.
Press switch 6. See figure 2-4.
The control head display will indicate the currently
selected switch configuration as follows:
(1). Switch 2 LED through
switch 8 LED’s indicate the pattern (if any). The
steadily illuminated LED indicates the pattern
number’s tens digit; the flashing LED indicates the
pattern number’s ones digit.
(2). The row of LED’s below the
V-shaped display will emulate the SignalMaster
pattern (if any).
(3). The first three LED’s on the
left of the V-shaped display indicate which relay
output (if any) is activated by this switch.
(4). The last three LED’s on the
right of the V-shaped display indicate switch opera-
tion: push-on/push-off (O), momentary (M), and
eight-second timed (T).
Therefore; switch 6 is configured
with pattern #46, no SignalMaster pattern, no
auxiliary relay, and push-on/push-off switch opera-
tion.
d.
Press switch 11 to add an auxil-
iary relay output to the switch 6 configuration.
Continue to press switch 11 until the “C” LED in the
V-shaped display is illuminated. The control head
display now indicates that switch 6 is configured
Содержание VISION