II. STROBE TUBE REPLACEMENT
After extended operation, occasionally check for flash tube degradation. Should the flash tube
misfire, have a noticeable decrease in light output, glow continuously or darken-replacement is
necessary.
WARNING
High voltages are present inside the light assembly. Wait at least 5 minutes after
shutting off the power before servicing the unit.
A. Disconnect power from the supply circuit and wait five minutes before opening unit to allow
all capacitors to discharge.
B. Loosen locking screw on lens and remove lens from housing by turning counter-clockwise.
C. Carefully remove the old strobe tube by grasping the connector and lifting upwards.
D. Replace lamp with Federal Signal part number K149130A. Install new strobe tube by fully
seating it into the receptacle on the printed circuit board.
E. Attach lens to housing by turning clockwise until seated.
F. Tighten locking screw on lens to secure.
III. SERVICE
The Federal factory will service your equipment or provide technical assistance with any prob-
lems that cannot be handled locally.
Any units returned to Federal Signal for service, inspection, or repair must be accompanied
by a Return Material Authorization. This R.M.A. can be obtained from a local Distributor or
Manufacturer’s Representative.
At this time a brief explanation of the service requested, or the nature of the malfunction,
should be provided.
Address all communications and shipments to:
Industrial Systems
2645 Federal Signal Drive • University Park, IL 60484-3167
Tel: 708-534-4756 • Fax: 708-534-4852
Email: [email protected] • www.federalsignal-indust.com
IV. REPLACEMENT PARTS
Description
Part Number
Strobe tube
K149130
Lens, Amber
K8589063
Lens, Blue
K8589063-01
Lens, Clear
K8589063-02
Lens, Green
K8589063-03
Gasket Kit*
K8589013
* Includes gasket for LP3P, LP3S, and LP3T