background image

2561511A

REV.  A  1002

Printed in U.S.A.

INSTRUCTION SHEET

FOR

MODELS SML6-2SML1F AND SML6-2SML1F30

SIGNALMASTER™ LIGHT ASSEMBLIES

SAFETY MESSAGE TO INSTALLERS

People’s lives depend on your safe installation of our

products. It is important to read, understand and follow all
instructions shipped with the products. In addition, listed
below are some other important safety instructions and
precautions you should follow:

To properly install this light: you must have a
good understanding of automotive electrical
procedures and systems, along with proficiency in
the installation and use of safety warning
equipment.

When drilling into a vehicle structure, be sure
that both sides of the surface are clear of
anything that could be damaged.

In order for the light to function properly, a
separate ground connection must be made. If
practical, it should be connected to the negative
battery terminal. At a minimum, it may be
attached to a solid metal body or chassis part
that will provide an effective ground path as long
as the light system is to be used.

Locate light control so the VEHICLE and
CONTROL can be operated safely under all
driving conditions.

Do not attempt to activate or deactivate light
control while driving in a hazardous situation.

You should frequently inspect the light to ensure
that it is operating properly and that it is
securely attached to the vehicle.

File these instructions in a safe place and refer to
them when maintaining and/or reinstalling the
product.

Failure to follow all safety precautions and instructions

may result in property damage, serious injury, or death to you
or others.

I.

GENERAL.

The Federal SignalMaster™ Models SML6-2SML1F and

SML6-2SML1F30 are six-lamp directional light assemblies
with two additional outer lamps controlled by a flasher PCB
assembly. The flasher assembly can be activated by either
+12Vdc or ground. Lens colors available are: amber (standard),
red, blue, and clear.

WARNING

These lights are intended for 

secondary

 warning

only. They are 

not

 intended for use as a primary

warning system.

II.

INSTALLATION.

A.

SignalMaster Light Assemblies.

Install the light assembly as described in the

mounting kit instructions, and route the cable near the
eventual location of the control unit.

CAUTION

Install the control unit in an adequately ventilated
area. Never install near heater ducts.

B.

Control Unit.

NOTE

Before selecting a mounting location for the control
unit, it is necessary to plan wiring and cable routing.

Use a Federal Signal SMC16 or SMC56 control unit.

Install the control unit and complete the wiring as described in
the control unit instructions.

 WARNING

Do not connect more than one, 6 or 8 head,
halogen SignalMaster assembly to a
SignalMaster controller or the SignalMaster
outputs of a SmartSiren. Electrical fire or
damage to the controller or siren will result.

C.

Flasher Connections.

1.

SMC56 Control Unit (ground activation via AUX
switch).

See figure 1. Connect the ten-conductor cable’s

pink lead to the fused +12Vdc (+BAT) position on the seven-
position connector. Connect the blue lead to ground. Using a
one-ampere fuse, connect the white wire to the seven-position
connector’s AUX OUT position. Connect the remaining wires as
shown in figure 1. The flasher will operate when the control
unit’s AUX switch is activated.

CUSTOMER

SUPPLIED

1/4"

BRN

GRN

RED

PINK

BLU

YEL

GRA

Y

PURP

ORN

290A3761B

10 CONDUCTOR
CABLE FROM
SIGNAL MASTER

18 AWG   DASH LIGHTS
18 AWG   AUX IN
18 AWG   CASE GND.
14 AWG   (-)GND
18 AWG   +BAT/IGN.
14 AWG   +BAT
18 AWG   AUX OUT

+BA

T

25 AMP

.

+BA

T/IGN

(-) GND

(-) CASE

GR

OUNG

A

UX IN

A

UX OUT

D

ASH

LIGHTS

WHITE

BR

O

W

N

GREEN

ORANGE

VIOLET

GRA

Y

YELLO

W

BLUE

WHT/BLU

WHT/GRN

WHT/RED

WHT/ORN

RED

LIGHT

OUTPUTS

SMC56

POWER AND

GROUND

WIRE STRIPPING
TYPICAL

EXTERNAL LAMP

CONNECTIONS

25A

1A

1A

WHT

Figure 1.