background image

See figure 4. All controls utilized during normal

operation of the SignalMaster directional light are located
on the front panel of the control unit. The LED display
simulates the light pattern being executed by the direc-
tional light.

A.

Slide Switch.

1.

LEFT (Position 1).

In this position, the light produces a left arrow

flashing pattern, instructing traffic to move left.

2.

CENTER OUT (Position 2).

In this position, a center out flashing pattern

is produced, instructing traffic to move around either side
of the vehicle.

3.

RIGHT (Position 3).

In this position, the light produces a right

arrow flashing pattern, instructing traffic to move right.

B.

WARN switch.

When this switch is pressed, an alternating

pattern is produced. The two middle lights activate
alternately with the two outside lights on each side. This
pattern will override any of the slide switch functions.

V.

SERVICE.

A.

General.

Servicing, other than cosmetic features, should be

performed by a qualified Federal Signal service center. If
the control unit is not working properly, disconnect all
electrical connections starting with the six-position power
connector. Remove the control unit from the mounting
bracket. Send the unit to the nearest authorized service
center or the Federal Signal service department.

Communication and shipments should be addressed to:

Service Department
Federal Signal Corporation
2645 Federal Signal Drive
University Park, IL 60466

1-800-433-9132

 After servicing is complete, perform a test of all

functions to ensure the control unit is operating properly.

B.

Replacement Parts List.

Description

Part Number

Printed Circuit Board Assembly

2001135

Knob, Pushbutton

8573065

Knob, Slide Switch

8536C1041

Bezel, Slide Switch

8573060

Connector, Female, 6-Position

140325-04

Bracket, Mounting

8573070

Screw, Hex Head, Mounting

7011164B-08

Lockwasher, 1/4"

7075078

Chassis

8573068

Cover

8573066

Microprocessor

SM1CB100

-4-

Figure 4.

Содержание Signalmaster 330132

Страница 1: ...e Federal SignalMaster Model 330132 is an economical low profile solid state directional light control that is designed to operate with the Federal Signal six lamp directional light assembly The unit is reversed polarity protected to avoid damage if the positive and negative power connections are connected incorrectly This model provides three distinctive directional signals left arrow right arrow...

Страница 2: ...res MUST be installed in the six position connector as shown in figure 3 WARNING Do not connect more than one 6 or 8 head halogen SignalMaster assembly to a SignalMaster controller or the SignalMaster outputs of a SmartSiren Electrical fire or damage to the controller or siren will result Figure 1 CAUTION Install the control unit in an adequately ventilated area Never install near heater ducts NOT...

Страница 3: ...while being careful not to scrape the wires on any sharp edges b If necessary cut the cable to the appropri ate length c Connect six 22 gauge wires and 16 gauge red wire to the terminal block as shown in figure 2 Positions 1 8 9 and 10 are not used Cut the unused white and blue wires at the cable s insulating sheath D Inspection and Final Installation 1 Ensure that there are no loose wire strands ...

Страница 4: ...itch functions V SERVICE A General Servicing other than cosmetic features should be performed by a qualified Federal Signal service center If the control unit is not working properly disconnect all electrical connections starting with the six position power connector Remove the control unit from the mounting bracket Send the unit to the nearest authorized service center or the Federal Signal servi...

Отзывы: