background image

C.

Electrical Connections.

WARNING

Failure to observe this WARNING may result
in fire, burns or blindness.

If shorted to vehicle frame, high current conductors
can cause hazardous sparks resulting in electrical
fires or molten metal.

DO NOT connect this system to vehicle battery until
ALL other electrical connections are made and
mounting of all components is complete.

Verify that no short circuits exist, before connecting
to the Positive (+) battery terminal.

The control unit is supplied with a six-position

connector and a eleven-position terminal block to perform
the electrical installation. User-supplied, 14-gauge red and
black wires are required for the (+) BAT and (-) GND
connections on the six-position connector. User-supplied,
18-gauge red and green wires are required for the (+) BAT/
IGN and CASE GROUND connections on the six-position
connector. Using figure 2 as a guide, complete this portion
of the installation as follows:

1.

Power Connections.

CAUTION

To avoid damage and ensure proper operation, the
red and black wires MUST be installed in the six-
position connector as shown in figure 3.

 WARNING

Do not connect more than one, 6 or 8 head,
halogen SignalMaster assembly to a
SignalMaster controller or the SignalMaster
outputs of a SmartSiren. Electrical fire or
damage to the controller or siren will result.

Figure 1.

CAUTION

Install the control unit in an adequately ventilated
area. Never install near heater ducts.

NOTE

When selecting a mounting location for the control
unit, it is necessary to keep in mind that the Signal
Master cable is 15-feet long. Plan wiring and cable
routing before installation.

1.

Select a mounting location for the control unit

that allows the vehicle and controls to be operated safely at
all times.

2.

Use the mounting bracket as a template and

scribe two drill position marks at the selected mounting
location.

CAUTION

Before drilling holes in ANY part of a vehicle, be
sure that both sides of the mounting surface are
clear of parts that could be damaged; such as brake
lines, fuel lines, electrical wiring or other vital parts.

3.

Drill two holes at the previously scribed

position marks.

4.

Secure the mounting bracket to the mounting

surface with two user-supplied, thread-forming, 1/4-20
screws.

-2-

Figure 2.

Содержание Signalmaster 330132

Страница 1: ...e Federal SignalMaster Model 330132 is an economical low profile solid state directional light control that is designed to operate with the Federal Signal six lamp directional light assembly The unit is reversed polarity protected to avoid damage if the positive and negative power connections are connected incorrectly This model provides three distinctive directional signals left arrow right arrow...

Страница 2: ...res MUST be installed in the six position connector as shown in figure 3 WARNING Do not connect more than one 6 or 8 head halogen SignalMaster assembly to a SignalMaster controller or the SignalMaster outputs of a SmartSiren Electrical fire or damage to the controller or siren will result Figure 1 CAUTION Install the control unit in an adequately ventilated area Never install near heater ducts NOT...

Страница 3: ...while being careful not to scrape the wires on any sharp edges b If necessary cut the cable to the appropri ate length c Connect six 22 gauge wires and 16 gauge red wire to the terminal block as shown in figure 2 Positions 1 8 9 and 10 are not used Cut the unused white and blue wires at the cable s insulating sheath D Inspection and Final Installation 1 Ensure that there are no loose wire strands ...

Страница 4: ...itch functions V SERVICE A General Servicing other than cosmetic features should be performed by a qualified Federal Signal service center If the control unit is not working properly disconnect all electrical connections starting with the six position power connector Remove the control unit from the mounting bracket Send the unit to the nearest authorized service center or the Federal Signal servi...

Отзывы: