background image

2561063B
REV.  B  1002
Printed in U.S.A.

INSTRUCTION SHEET

FOR

SIGNALMASTER™ MODEL 330132

SAFETY MESSAGE TO INSTALLERS AND USERS

People’s lives depend on your safe installation of our

products. It is important to read, understand and follow all
instructions shipped with the products. In addition, listed
below are some other important safety instructions and
precautions you should follow:

To properly install this light: you must have a
good understanding of automotive electrical
procedures and systems, along with proficiency
in the installation and use of safety warning
equipment.

DO NOT install equipment or route wiring  in
the deployment path of an air bag.

When drilling into a vehicle structure, be sure
that both sides of the surface are clear of any-
thing that could be damaged.

In order for the light to function properly, a
good ground connection must be made. At a
minimum, it must be attached to a solid metal
body or chassis part that will provide an effec-
tive ground path as long as the light system is
to be used.

Locate light control so the VEHICLE and
CONTROL can be operated safely under all
driving conditions.

Do not attempt to activate or deactivate light
control while driving in a hazardous situation.

You should frequently inspect the light to en-
sure that it is operating properly and that it is
securely attached to the vehicle.

File these instructions in a safe place and refer
to them when maintaining and/or reinstalling
the product.

Failure to follow all safety precautions and instruc-

tions may result in property damage, serious injury, or
death to you or others.

I.

GENERAL.

The Federal SignalMaster™ Model 330132 is an

economical, low profile, solid state, directional light control
that is designed to operate with the Federal Signal six-
lamp directional light assembly. The unit is reversed
polarity protected to avoid damage if the positive and
negative power connections are connected incorrectly.

This model provides three distinctive directional

signals: left arrow, right arrow, and center out. In addition,
an alternating flash pattern produces a warning signal for
use when a directional signal may not be appropriate.

When a directional signal is selected, the lamps are
individually illuminated in a sequential sweeping motion
until all six lamps are illuminated.

II.

SPECIFICATIONS.

Input Voltage

11VDC to 16VDC.

Polarity

Negative ground only.

Operating Temperature

-30

°

 C to +65

°

 C.

  Range

Standby Current

Zero amperes.

+BAT Fuse

25 amperes.

+IGN/BAT Fuse

1 ampere.

Output Drive

6, 27 watt lamps.

  Capability (Total)

Flash Rate:

Directional

35 patterns/min.

Warn

60 patterns/min.

Dimensions:

Height

1-1/2"

Width

6-1/8"

Depth

5"

Shipping Weight

2.0 lbs

III. INSTALLATION.

A.

SignalMaster Light Assembly.

Install the light assembly as described in the

instructions packed with the mounting kit. Route the cable
near the eventual location of the control unit.

B.

Control Unit.

WARNING

When installing equipment inside air bag equipped
vehicles, the installer MUST ensure that the equip-
ment is installed ONLY in areas recommended by
the vehicle manufacturer.

Failure to observe this warning will reduce the
effectiveness of the air bag, damage the air bag, or
potentially damage or dislodge the equipment,
causing serious injury or death to you or others.

See figure 1. The supplied mounting bracket

allows the control unit to be mounted in a variety of
positions. To install the control unit, proceed as follows:

Содержание Signalmaster 330132

Страница 1: ...e Federal SignalMaster Model 330132 is an economical low profile solid state directional light control that is designed to operate with the Federal Signal six lamp directional light assembly The unit is reversed polarity protected to avoid damage if the positive and negative power connections are connected incorrectly This model provides three distinctive directional signals left arrow right arrow...

Страница 2: ...res MUST be installed in the six position connector as shown in figure 3 WARNING Do not connect more than one 6 or 8 head halogen SignalMaster assembly to a SignalMaster controller or the SignalMaster outputs of a SmartSiren Electrical fire or damage to the controller or siren will result Figure 1 CAUTION Install the control unit in an adequately ventilated area Never install near heater ducts NOT...

Страница 3: ...while being careful not to scrape the wires on any sharp edges b If necessary cut the cable to the appropri ate length c Connect six 22 gauge wires and 16 gauge red wire to the terminal block as shown in figure 2 Positions 1 8 9 and 10 are not used Cut the unused white and blue wires at the cable s insulating sheath D Inspection and Final Installation 1 Ensure that there are no loose wire strands ...

Страница 4: ...itch functions V SERVICE A General Servicing other than cosmetic features should be performed by a qualified Federal Signal service center If the control unit is not working properly disconnect all electrical connections starting with the six position power connector Remove the control unit from the mounting bracket Send the unit to the nearest authorized service center or the Federal Signal servi...

Отзывы: