background image

handset handle, an “off hook” indicator LED, a page receive speaker with volume control, and 10
ft cable with 25-pin D-subminiature connector. To install the desktop unit follow the steps de-
scribed below:

1. Install the remote subset enclosure within 10 ft of the desktop handset unit as described in

Section A and make electrical connections as described in the Section E. The suggested
location for a remote subset with desktop unit is the knee-well of the desk.

2. Plug the 25-pin D-subminiature connector to the 25 pin receptacle of the remote subset and

fasten it with the two screws provided.

3. Test the station for proper operation.

E. Electrical Connections (see Fig. 1, 4, 5)

WARNING

To avoid electrical shock, do not connect wires when power is applied.

The enclosure has a motherboard that provides designated screw terminal blocks for easy and
trouble free connections of system cable. It allows sufficient space for the system cable to be
looped in and out. The wires should be properly dressed and terminated inside the enclosure. The
SelectFone stations are electrically paralleled. This allows system expansion by simply extending
the system cable from the nearest SelectFone station.

Wire  the  station  carefully  by  following  the  wire  colors  and  using  the  spade  lugs  as  shown  in
Figure 4. Perform all electrical wiring per the National Electrical Code.

a. 120 VAC Power Connection

All AC power wiring to the SelectFone station is made at the 3-position terminal block JP1
mounted on the motherboard. Connect the black (HOT) 14 AWG conductor of the incoming
and outgoing cable to H terminal. Connect white (NEUTRAL) 14 AWG conductor to the
terminal marked N. Connect the green/yellow (earth ground) 14 AWG conductor to the ter-
minal marked GND.

A green 14 AWG ground conductor should be part of the system cable where no conduit or
non- metallic conduit is used. If a non-metallic enclosure is used with metallic conduit and
cable without ground conductor, there absolutely must be an electrical bond between conduit
and terminal marked GND at terminal block JP1 of the SelectFone station.

WARNING

No SelectFone station should be installed or operated without having proper

ground continuity.

b. 24VDC Power Connection for 24VDC SelectFone

The 24VDC SelectFone system stations are designed for operation from a 24VDC,
rechargeable battery. A charger can be connected to maintain the batteries. Ground the
negative side of battery only at one point for the system to reduce the hum and noise in the
24VDC SelectFone system.

WARNING

Do not operate 24VDC SelectFone system stations from a charger without a 24V battery

connected to it because high, no load voltage (30V to 40V) of a 24V charger can damage

the equipment. Never connect 24VDC SelectFone station to a supply

voltage greater than 28VDC.

-5-

Содержание SELECTFONE SF-1245X-024

Страница 1: ...unications and shipments to FEDERAL SIGNAL CORPORATION Electrical Products Division Service Department 2645 Federal Signal Drive University Park IL 60466 3195 MODEL SELECTFONE INSTRUCTION SHEET FOR FE...

Страница 2: ......

Страница 3: ...acilities and manufacturing packaging and processing plants A typical SelectFone intercom station features an impact resistant Cycolac handset with noise canceling dynamic transmitter and a receiver w...

Страница 4: ...l as local codes The selection of the mounting location for the device its controls and the routing of the wiring is to be accomplished under the direction of the facilities engineer and the safety en...

Страница 5: ...66 an equivalently rated cable gland or conduit hub must be used when connecting to the indoor outdoor station enclosure 1 Plan all the wiring and cable routing with the following guidelines in mind W...

Страница 6: ...hook switch and a channel selector switch It has a push to page switch located in the handset handle an off hook indicator LED and a 10 ft cable with 25 pin D subminiature connector To install the pa...

Страница 7: ...rform all electrical wiring per the National Electrical Code a 120 VAC Power Connection All AC power wiring to the SelectFone station is made at the 3 position terminal block JP1 mounted on the mother...

Страница 8: ...draw per station is less then sine signal MAXIMUM CABLE DISTANCE PER POWERLINE BRANCH 14AWG CABLE 12 AWG CABLE 10 AWG CABLE 8 AWG CABLE NUMBER TOTAL BETWEEN TOTAL BETWEEN TOTAL BETWEEN TOTAL BETWEEN O...

Страница 9: ...terminal of the speaker to the terminal marked C at the terminal block JP2 and connect VE of the speaker terminal to the terminal marked 8 for 8 ohm impedance speaker or to the terminal marked 16 for...

Страница 10: ...et receiver If necessary open the cover of the line balance assembly and adjust the page line loading by turning the control to the point where little or no page is audible in the handset receiver In...

Страница 11: ...Pull out template for use during installation...

Страница 12: ......

Страница 13: ......

Страница 14: ...Pull out template for use during installation...

Страница 15: ...ground fault or leakage to ground Low Level Audio At All Stations This problem can occur when there is a dead short across any channel or page line The system will still function but the audio level w...

Страница 16: ...a Return Material Authorization The R M A can be obtained from the local Manufacturer s Representative or by calling the factory At this time a brief explanation of the service requested or the natur...

Страница 17: ...sure Mounting Holes PAGE L1 L2 L1 PARTY1 L2 L1 PARTY2 L2 L1 PARTY3 L2 L1 PARTY4 L2 L1 PARTY5 L2 HANDSET C 8 16 IN OUT ISO SPKR MUTE G N D N H A C SLO BLO 1 2 A CN1 PREAMP JP2 CN3 L2 L1 JP1 CN2 8 68 5...

Страница 18: ...2 12 KEY A Enclosure Mounting Holes SELECTFONE INDOOR OUTDOOR STATION MODEL SF 1245X SF 1241X FIG 2 6 5 2 1 8 14 6 2 12 6 2 10 00 14 94 290A4034 02 A...

Страница 19: ...13 3 PANEL CUT OUT TEMPLATE FOR SF 1015P SF 1011P FIG 3 5 50 3 25 0 25 0 25 290A4034 03 B A KEY A Mounting Holes B Cut Out...

Страница 20: ...Y5 L1 L2 PARTY1 PARTY2 PARTY4 PARTY3 L1 L1 L1 L1 L1 L2 L2 L2 PAGE L2 L2 WHITE GRAY WHITE RED AC N H CABLE 2 RED SPEAKER 16 OHM MUTE OUTDOOR WALL MOUNT HANDSET SPEAKER STATION INDOOR PANEL AND DESKTOP...

Страница 21: ...ER STATION INDOOR PANEL AND DESKTOP HANDSET SPEAKER SUB STATION 8 CONDUCTOR 120VAC PAIR 14AWG TWISTED PAGE PARITY LINE PAIRS 18AWG TWISTED ONE SINGLE CONDUCTOR 14AWG ONE SINGLE CONDUCTOR 18AWG 430 O D...

Страница 22: ...STATION 16 CONDUCTOR 24VDC PAIR 14AWG TWISTED PAGE PARITY LINE PAIRS 18AWG TWISTED ONE SINGLE CONDUCTOR 14AWG ONE SINGLE CONDUCTOR 18AWG 630 O D 2 TO MUTE BETWEEN ANY NUMBER OF STATIONS CONNECT THE A...

Страница 23: ...D PAGE PARITY LINE PAIRS 18AWG TWISTED ONE SINGLE CONDUCTOR 14AWG ONE SINGLE CONDUCTOR 18AWG 430 O D 2 TO MUTE BETWEEN ANY NUMBER OF STATIONS CONNECT THE APPLICABLE STATION S MUTE TERMINALS TOGETHER 1...

Страница 24: ...ed 9 04 Printed in U S A 8 LINE BALANCE ASSEMBLY MODEL SF 1000LB FIG 6 KEY A Mounting Holes B Page Line Balance Adjustment L1 PARTY 5 L2 PARTY 4 L1 L2 PARTY 3 L1 L2 PARTY 2 L1 L2 PARTY 1 L1 L2 PAGE L1...

Отзывы: