11
Selecting a Flash Pattern
Installation and Service Instructions
Federal Signal
www.fedsig.
3.
Briefly touch the program wire (yellow) to +12 Vdc.
NOTE
: Holding the pattern wire (yellow) to +12 Vdc for 5 to
9 seconds returns you to default flash pattern 1. Holding the
pattern wire (yellow) to +12 Vdc for 10 seconds or more brings
you to default flash pattern 2.
4.
When the pattern you want displays, let it run for 15 seconds
to store it in memory.
5.
Secure the entire QuadraFlare Warning Light assembly to
the mounting sur face with the previously retained screws.
Table 3 QuadraFlare Models
Number Flash Pattern
1*
DoubleFlash 150 — Simultaneous (default flash pattern 1)
2
DoubleFlash 150 — Alternating Horizontal
3*
Fedpulse 75 — Simultaneous
4
Fedpulse 75 — Alternating Horizontal
5*
DoubleFlash 75 — Simultaneous
6
DoubleFlash 75— Alternating Horizontal
7*
QuadFlash 75 — Simultaneous
8
QuadFlash 75 — Alternating Horizontal
9
SingleFlash 375 — Alternating Horizontal
10
SingleFlash 375 — Simultaneous
11
SingleFlash 150 — Alternating Horizontal
12*
SingleFlash 150 — Simultaneous
13
SingleFlash 75 — Alternating Horizontal
14*
SingleFlash 75 — Simultaneous
15
VariFlash — Alternating Horizontal
16
VariFlash — Simultaneous
17
SteadyPulse 75
18
Alternating Random Flash
19
Alternating/Simultaneous Random Flash
20
3 Flashes Steady (default flash pattern 2)
21
Steady Brake