10
Selecting a Flash Pattern
QuadraFlare
®
Federal Signal
www.fedsig.com
Looking at the back of the unit with the vent hole on your
right, the top of the light is controlled with the red wire and the
bottom is controlled with the white wire. See Figure 3. If the light
has one side with red LEDs, the red wire controls that side and
the white controls the other side (amber, blue, white, green, or
red).
Wiring the QuadraFlare
The Model QuadraFlare Warning Light assembly operates on
12 Vdc. Five 12-inch long lead wires are supplied for making
electrical connections to the QuadraFlare Warning Light
assembly. Ensure that all wires are properly connected and
insulated appropriately.
To make electrical connections:
1.
Using 18 AWG (minimum) wire, connect the red (+) lead to
the positive power source terminal and the black (–) lead to
the negative power source terminal.
2.
On the QuadraFlare, connect the white (+) lead to the same
positive power source terminal as the red (+) lead to operate
or switch to power up independently of each other.
3.
On all models, the violet wire (low power, dimming) is
connected to +12 V power source. Removing the power
restores the unit back to full power.
4.
Apply power and test the QuadraFlare Warning Light
assembly for proper operation.
Selecting a Flash Pattern
The QuadraFlare has 26 selectable flash patterns with Pattern 1
as the default. See Table 2 for a description of each pattern and
the order in which it is stored in memory.
To select flash patterns:
1.
Remove and retain the four #6 by 2-inch. mounting screws.
2.
Apply power to the light.