12
4. Connect the black wire to the negative battery
terminal. A secure mechanical and electrical
connection is required.
3-5. INSPECTION AND FINAL INSTALLA-
TION
1. Plug the eleven-position connector into the
mating connector on the unit, and apply
pressure until it locks into place.
HIGH CURRENT ARCING: Do not connect this
system to the vehicle battery until ALL other
electrical connections are made and you have
verified that no shorts exist. High current
conductors can cause hazardous sparks or burning
wire, resulting in electrical fires.
2. Connect the red (+) wire to the positive
(+) terminal of the power source. A secure
mechanical and electrical connection is
required.
3-6. TESTING AFTER INSTALLATION.
All effective sirens and horns produce loud sounds
(120 dB) that may cause permanent hearing loss.
Always minimize your exposure to siren sound and
wear hearing protection. Do not sound the siren
indoors or in enclosed areas where you and others
will be exposed to the sound.
After installation, test the electronic siren,
including horn operation, to ensure that it is
operating properly.
After testing is complete, provide a copy of this
manual to all operating personnel.