![Federal Signal Corporation Navigator Lightbar Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/federal-signal-corporation/navigator-lightbar/navigator-lightbar_installation-operation-and-service-instructions_3912650017.webp)
17
Navigator Lightbar
Installation, Operation, and Service Instructions
10-inch All-Stationary Navigator with a 4-Conductor Control Cable
The 10-inch all stationary Navigator has a 4-conductor cable exiting the lightbar. Each wire has the following
function:
BLACK
WIRE:
Attach this wire to a known good vehicle ground.
MODE 1:
Ap12 Vdc to the
RED
wire activates flashing mode. This wire must be on a switched feed that is
fused at 10 A.
WHITE LIGHT:
Ap 12 Vdc to the
WHITE
wire while the lightbar is flashing activates the white LEDs in the
lightheads, if installed (White Light Enable). If used, this wire must be on a switched feed that is fused at 10 A.
WORK LIGHT:
Apply + Vdc to the
GREEN
wire activates flashing.
Figure 4
Wire functions for 4-conductor cable (10-inch all stationary)
WORKLIGHT
WHITE LIGHT ENABLE
GREEN
WHITE
+POWER
RED
–GROUND
BLACK
HIGH-SIDE (12 V dc) SWITCHED OUTPUTS
4-CONDUCTOR CABLE
FROM LIGHTBAR
INSTALLER SUPPLIED
SUPPLIED WITH LIGHTBAR
FUSE RATINGS ARE BASED ON A
STANDARD OPTION INSTALLATION.
IF MULTIPLES OF ANY OPTION ARE
INSTALLED, ADJUST THE FUSE
SIZE AS REQUIRED.
40 A
40 A
(EXTEND LEADS WITH
16 AWG OR THICKER)
10-inch or 18-inch All-Rotator Navigator with a 4-Conductor Control Cable
A 10-inch or 18-inch all-rotator
N
avigator has a 4-conductor cable exiting the lightbar. Each wire has the
following function:
BLACK
WIRE:
Attach this wire to a known good vehicle ground.
90 RPM:
Ap12 Vdc to the
RED
wire turns on the rotators, which spin at 90 RPM. This wire must be on a
switched feed that is fused at 10 A
WHITE LIGHT:
Ap 12 Vdc to the
WHITE
wire while the while the rotators are active activates the white in
the rotators configured with white light. The rotator LEDs are white to the front and a primary color to the rear. If
used, this wire must be on a switched feed that is fused at 10 A.
120 RPM:
Ap12 Vdc to the
GREEN
wire turns on the rotators, which spin at 120 RPM. This wire must be
on a switched feed that is fused at 10 A.
Содержание Navigator Lightbar
Страница 2: ......