background image

3-2 

Therefore, for a person to hear a 

warning signal in an industrial area, 

the sound level intensity of that signal 

must also be at least 90dB. In this 

situation, any point receiving a signal 

having less than 90dB intensity is 

considered to be outside the effective 

range of the siren. 

 

 

In business districts an ambient 

noise level of 80dB is common, and in 

residential areas, 68dB of ambient 

noise is typical. Assuming a 10dB loss 

per distance doubled and a 68dB 

minimum sound level, the effective 

range of the MOD6024 is 

approximately 3900 feet. 

 
 

Wind speed and direction often 

affect the  propagation of sound from 

the siren. Consequently, the direction 

of the prevailing wind may also be a 

factor to consider when selecting the 

installation site(s) of a small, one or 

two-siren system. For example, if the 

prevailing wind is from the west, it 

may be desirable to install the siren 

toward the western edge of the area to 

be covered. 

 

 

Other factors to consider before 

selecting the installation site include 

the availability of electrical power, the 

ease of installation and maintenance, 

the height of surrounding 

obstructions, and security against 

vandalism. 

 

 

The Modulator Controller (MCP) 

comes with an optional and phase-

phase option (turbo mode) which can 

increase the sound level output by 3db 

in one of two directions (180

°).  When installing the Modulator with this option it should be mounted in the 

direction of the arrow on the mounting base, or the 1” fitting at the base of the siren. 

 

 

3-2.  SIREN INSTALLATION.

 

 

 

A. 

General.

 

 

 

 

Most siren installations are 

one of two types: Pole Mount or Flat 

Surface Mount. These two 

configurations make it possible to 

install a siren in almost any situation. 

If the installations in this paragraph 

are not suitable, modification of one of 

the configurations may be practical. 

 

 

 

A siren is typically installed 

40  - 50  ft. above the ground. If the 

installation is located less than 50 ft. 

above the ground, the sound intensity 

at close range may increase, but at the 

same time the effective range of the 

siren may be reduced. Conversely, if 

the siren is located more than 50  ft. 

above ground, the effective range of 

the siren may increase, but the sound 

may skip over areas closer to the 

siren. These variables may make it 

desirable to test the sound coverage of 
the siren at various heights and 

locations whenever possible. 

 

 

B. 

Pole Mounting.

 

 

 

 

A typical pole-mounted siren 

installation is shown in figure 3-1. The 

siren is mounted on a Class 2 utility 

pole (ANSI type wooden pole or 

equivalent) with a minimum 

horizontal ground stress rating of 

3,700 pounds (1682 Kg).  (Insure that 

soil loads will conform to this size 

utility pole).  It is attached to the pole 

by means of legs, as shown in figure 3-

2. 

 

 

 

Using the 3 ft. long angle 

iron legs, the siren is mounted on the 

Class 2 utility pole as follows: 

 

 

 

1.  Uncrate the siren and 

remove the nuts that hold the siren on 

the shipping base. Lift the siren 

approximately 3-1/2 ft. with a crane or 

hoist. 

 

 

 

2.  Install the four legs on 

the siren mounting plate, as shown in 

figure 3-2. Use two 1/2" bolts, nuts and 

lockwashers (provided) for each leg. 

Do not tighten the bolts completely. 

 

 
 
 

Содержание MOD1004

Страница 1: ...MODULATOR SERIES SPEAKER ARRAYS INSTALLATION AND MAINTENANCE INSTRUCTIONS 255253G REV G 12 99 ...

Страница 2: ... 1 1 4 Signal Description 1 2 1 5 Features 1 2 SECTION II SPECIFICATIONS 2 1 Siren 2 1 SECTION III INSTALLATION 3 1 Siren Location 3 1 3 2 Siren Installation 3 1 3 3 Speaker Connections 3 3 3 4 Pre operation checkout 3 3 SECTION IV SERVICE AND MAINTENANCE 4 1 General 4 1 4 2 Preventive Maintenance 4 1 4 3 Driver Replacement 4 1 ...

Страница 3: ... that it is operating properly Test the system regularly to confirm that it will be operational in an emergency If future service personnel do not have these warnings and all other instructions shipped with the equipment to refer to the siren system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss or other bodily injury File these in...

Страница 4: ...le at all times to authorize the activation of the sirens When sirens are used out of doors people indoors may not be able to hear the warning signals Separate warning devices or procedures may be needed to effectively warn people indoors The sound output of sirens is capable of causing permanent hearing damage To prevent excessive exposure carefully plan siren placement post warnings and restrict...

Страница 5: ... access to the product or labor charges for removal and re installation of the product Batteries are not covered under warranty This warranty does not extend to any unit which has been subjected to abuse misuse improper installation or which has been inadequately maintained nor to units which have problems relating to service or modification at any facility other than the Federal factory or author...

Страница 6: ...h have the following sound output rating at 100 feet MOD1004 106dBC MOD2008 112dBC MOD3012 115dBC MOD4016 118dBC MOD6024 121dBC MOD6048 125dBC Based on measurements at 500 feet 1 4 FREQUENCY RESPONSE The Modulator Series siren provides virtually flat frequency response from 200 2000 Hertz This gives the siren the ability to produce loud and clear voice messages as well as the ability to produce a ...

Страница 7: ...1 2 Figure 1 1 Modulator series Outline Drawing ...

Страница 8: ... of Active Modules 1 Power 400 Watts dB output 106 dBC 100 feet Height of Speaker Array 43 17 Weight 181 lbs MOD2008 Number of Active Modules 2 Power 800 Watts dB output 112 dBC 100 feet Height of Speaker Array 63 70 Weight 296 lbs MOD3012 Number of Active Modules 3 Power 1200 Watts dB output 115 dBC 100 feet Height of Speaker Array 84 30 Weight 411 lbs MOD4016 Number of Active Modules 4 Power 160...

Страница 9: ...tts dB output 121 dBC 100 feet Height of Speaker Array 146 08 Weight 760 lbs MOD6048 Number of Active Modules 6 Power 4800 Watts dB output 125 dBC 100 feet Height of Speaker Array 146 08 Weight 928 lbs The bottom module of the siren is a passive device that does not contain any drivers Its functional use is to complete the horn formed by the bottom and the first active module ...

Страница 10: ...s the distance from the siren increases sound level losses accumulate These losses are a result of weather conditions the terrain obstructions in the sound path the pitch of the sound and the height of the siren Optimum sound propagation conditions exist when there are no obstructions in the sound path the terrain is flat and the air is calm Under these conditions each time the distance from the s...

Страница 11: ...base or the 1 fitting at the base of the siren 3 2 SIREN INSTALLATION A General Most siren installations are one of two types Pole Mount or Flat Surface Mount These two configurations make it possible to install a siren in almost any situation If the installations in this paragraph are not suitable modification of one of the configurations may be practical A siren is typically installed 40 50 ft a...

Страница 12: ... Series Siren on a flat roof or other flat surface proceed as follows 1 If desired construct a platform for mounting the siren which must be capable of supporting at least 800 lbs as well as withstanding a siren wind load of 100 mph The platform must also be capable of distributing its own weight plus the siren to a value that is safe for the mounting surface Platform design and construction detai...

Страница 13: ...y from module to module Model MOD4016 and MOD6024 contain junction boxes in series with the 50 foot cable to allow connection to the speaker array Refer to list below for number of wires per module and how many wires are used MOD1004 8 wires only 4 are used MOD2008 8 wires all are used MOD3012 16 wires only 12 are used MOD4016 16 wires all are used MOD6024 24 wires all are used MOD6048 24 wires al...

Страница 14: ......

Страница 15: ...3 5 ...

Страница 16: ...ct FWS Service Department Federal Signal Corporation 2645 Federal Signal Drive University Park Illinois 60466 1 800 548 7229 WARNING The output level of a Modulator Series Siren is capable of causing permanent hearing damage Therefore ALWAYS wear hearing protection when performing tests or maintenance on the siren To prevent the siren from sounding always turn off the power to the siren at the dis...

Страница 17: ...ire has been severed To determine the location of the bad driver refer to the wiring table in Section 3 and Figure 3 3 To replace a defective driver remove the four Hex head 1 4 inch mounting bolts that are holding the inspection plate Make sure the flat washer and split washer are not misplaced Note the color and location of the wires going to the driver Remove the wire from the terminals on the ...

Отзывы: