Federal Signal Corporation JETSTROBE PLUS SJ1P Скачать руководство пользователя страница 4

-4-

3.

Repeat the above steps for the other

side facing reflector/flash tube assembly.

C.

Function Activation.

1.

Standard (Quadruple Flashing) Mode.

The standard mode in four head and

six head models is activated by applying 12VDC to
the control cable’s heavy red wire. Activate the
standard mode in ten head models by applying
12VDC to the control cable’s heavy red wire and to
the red/white wire.

2.

No-Dark Time Action Mode.

NOTE

Available ONLY in ten head models (SJ3P
and SJL3P).

Activate the standard mode (described

above), and apply 12VDC to the control cable’s blue
wire.

3.

Front Cutoff.

Front cutoff in four and six head

models is activated by applying 12VDC to the control
cable’s red/white wire.

Front cutoff in ten head models is

accomplished by disconnecting the 12VDC to the
control cable’s red/white wire. Standard or action
front cutoff modes are obtained depending on the
voltage applied to the control cable’s blue wire.

4.

Low Intensity Double Flash Mode.

Activate the standard, action, or front

cutoff mode (described above), and apply 12VDC to
the control cable’s yellow wire.

5.

Front Only Mode.

Front only mode (available only in ten

head models) is activated by simultaneously applying
12VDC to the power cable red/white wire and discon-
necting 12VDC from the red wire. Standard, action,
or low intensity modes are obtained depending on the
voltage applied to the blue and yellow wires.

IV.

BASIC MAINTENANCE.

WARNING

High voltages are present inside the lightbar.
Wait at least ten (10) minutes, after shutting
off power, before servicing this unit. Failure
to do so may result in property damage, seri-
ous injury, or death to you or others.

Disconnect ALL power to the lightbar before
any maintenance is performed.

A.

Cleaning the Plastic Domes.

Ordinary cleaning of the plastic domes can

be accomplished by using mild soap and a soft rag.
Should fine scratches or a haze appear on the domes,
they can ordinarily be removed with a non-abrasive,
high quality automotive paste wax.

WARNING

Crazing (cracking) of domes will cause reduced
effectiveness of light system. Do not use clean-
ing agents (which will cause crazing) such as
strong detergents, solvents, or petroleum prod-
ucts. If crazing of domes does occur, reliability
of light for emergency warning purposes may
be reduced until domes are replaced.

B.

Halogen Lamp Replacement.

WARNING

A serious injury may result if lamp is touched
when hot. Always allow lamp to cool before
removing. Halogen lamps are pressurized and
if broken can result in flying glass. Always
wear gloves and eye protection when handling
the lamps.

CAUTION

Service life of lamp will be shortened if glass
portion is touched. If glass has been handled,
clean carefully with a grease solvent.

Replace 50-watt halogen lamps with

Federal Part Number 8107A119 and 35-watt with
8548A028.

Figure 5. JSFEI Installation.

SIDE FACING REFLECTOR ASSEMBLY

NOTCHED
CORNERS

INSERT

CLIP(2)

MODEL JSFEI-A
(AMBER) STROBE
INSERT(ORDER
SEPERATELY, AND
SPECIFY COLOR REQUIRED.)

290A2749

NOTE:  NOTCHED CORNERS FACE TOWARD FRONT OF  LIGHTBAR

#4-40 THD.
FRM. SCREW
(2)

Содержание JETSTROBE PLUS SJ1P

Страница 1: ...st aerodynamic strobe bar available today It utilizes the latest in solid state electronics and strobe technology The highly effective quadruple flash pattern is produced by powerful highly efficient and reliable power supplies The ten head models feature an innovative no dark action pattern All models incorporate a low intensity double flash mode which reduces power consumption by 60 Six base mod...

Страница 2: ...e holes in the insert with the holes in the clips and secure with two 4 screws Figure 1 SJ1P and SJL1P Wiring Diagram 290A2693 01 LEFT ALLEY RIGHT ALLEY TO SPEAKER GROUND INCOMING CABLE FLASHER GND STUD INTERNAL WIRING EXTERNAL WIRING LOW INTENSITY OPTION RED BLU YEL GRA GRN ORN BRN BLK RED WHT BLK WHT BRN WHT FRONT CUT OFF POWER SUPPLY 4 HEAD CUSTOMER SUPPLIED SUPPLIED WITH LIGHTBAR POWER IGN TO ...

Страница 3: ...YEL BLU RED RED 5 4 3 2 1 10 9 8 7 6 STROBE X RIGHT ALLEY STROBE 4 1 STROBE 4 2 STROBE 4 3 6 6 6 5 STROBE 6 4 STROBE 6 2 WHT GRN WHT ORN BRN BRN BLK WHT GRN ORN BRN BRN WHT STROBE 6 3 STROBE 4 4 6 1 TAKEDOWN WORK LIGHT FRONT REAR FLASHING BRAKE TAIL LIGHT TAKEDOWN WORK LIGHT ROTATOR 90 OR 175 FPM TRAFFIC CLEARING LIGHT OR STEADY BURNING RED WIRING DIAGRAM FOR MODELS SJ3P WITH SPEAKER AND SJL3P WIT...

Страница 4: ...gh voltages are present inside the lightbar Wait at least ten 10 minutes after shutting off power before servicing this unit Failure to do so may result in property damage seri ous injury or death to you or others Disconnect ALL power to the lightbar before any maintenance is performed A Cleaning the Plastic Domes Ordinary cleaning of the plastic domes can be accomplished by using mild soap and a ...

Страница 5: ...ly 3 Install the new reflector flash tube assembly Part No 8552443 by performing the previous steps in reverse order E Strobe Power Supply Fuse Replacement WARNING High voltages are present inside the lightbar Wait at least ten 10 minutes after shutting off power before servicing this unit Failure to do so may result in property damage seri ous injury or death to you or others Disconnect ALL power...

Страница 6: ...shers 6 Remove the leads from the old driver and connect to the new driver 58 watt driver must be unsoldered and then re soldered 7 Reinstall the driver Ensure that washers are installed correctly see figure 5 Recon nect the driver lead wires to the light assembly feed wires Secure connections with wirenuts 8 Reinstall cone Ensure that washers are installed correctly see figure 6 9 Replace grille ...

Отзывы: