The following table list the Functions with their descriptions.
Table 9 Function Definitions
Fields
Description
Arm
The Arm function activates the amplifier in an Informer. The
Informer must be armed or activation functions will not operate.
Once armed, the Informer remains armed for approximately
4-1/2 minutes.
Disarm
Disarms the Informer.
Wail
Sound Wail siren tone.
Pulsed Wail
Sound Pulsed Wail siren tone.
Alternate Wail
Sound Alternate Wail siren tone.
Steady
Sound Steady siren tone.
Pulsed Steady
Sound Pulsed Steady siren tone
Alternate Steady
Sound Alternate Steady siren tone.
Auxiliary
Sound Auxiliary siren tone. The Auxiliary tone is normally set for
Westminster Chimes.
Digital Voice -
n
Enter the desired digital voice number to run, and then click OK.
For Informer devices, enter between 1-250.
Dynamic Voice
Plays a sequence of digital voice messages specified at the time
of activation.
Quiet Test
Performs a self-test of the Informer unit, amplifier and speakers by
sounding an inaudible tone.
Cancel (Use instead
of Master Reset)
Terminates active function. Assign a hotkey to the Cancel Function
if performing a master reset is not desired. A Cancel will not reset
a Latched relay; a master reset will.
Master Reset
Terminates active function and clears latched status. Typically a
hotkey is assigned as a Master Reset for all Informers.
Phase Off
Not used.
Low Power
Reduces unit power to approximately 20 dB below maximum
volume. This selection overrides front panel controls.
High Power
Increases unit to full output. This selection overrides front panel
controls.
Power Attenuation
(for Informer15,
Informer100, and
versions 4.1 or later
of I-IP-IO and I-IPW)
Set the number of dB SPL to reduce the speaker volume during
functions. 0 dB (of attenuation) produces full volume. For example,
the Informer100 produces approximately 114 dB SPL at 10 feet
with no Power Attenuation. Using Power Attenuation allows a
maximum adjustment of 20 dB. If all 20 dB of Power Attenuation is
used, the Informer100 produces 94 dB of SPL at 10 feet.
Ambient Attenuation
(for Informer15,
Informer100 and
versions 4.1 or later
of I-IP-IO and I-IPW)
Set the noise level threshold for ambient attenuation to begin. As
the sound level drops below the Ambient Attenuation setting, the
output of the speaker is automatically lowered. The maximum
amount of Power and Ambient attenuation is 20 dB