11
Federal Signal
signaling.fedsig.com
Replacement Parts
Contact the factory for spare parts availability and part numbers. Typical spare parts are listed below. Due to certification,
certain component parts are not available for field replacement. Units with this type of damage must be either replaced
entirely or returned to Federal Signal for service.
Table 2 Replacement Part
Description
Part Number
70 V
RMS
, Loudspeaker Kit
(Includes PCBAs, Bracket, Driver, & Mounting Screws)
K859501405-070
100 V
RMS
Loudspeaker Kit
(Includes PCBAs, Bracket, Driver, & Mounting Screws)
K859501405-100
Table 3
Accessories
Description
Part Number
Indicator Ring/Legend Kit, Black
G-KIT-RP-BK
Indicator Ring/Legend Kit, Blue
G-KIT-RP-B
Indicator Ring/Legend Kit, Green
G-KIT-RP-G
Indicator Ring/Legend Kit, Magenta
G-KIT-RP-M
Indicator Ring/Legend Kit, Red
G-KIT-RP-R
Indicator Ring/Legend Kit, Yellow
G-KIT-RP-Y
E-Box Endcap with M20 Opening
K859500805-02
E-Box Endcap with M25 Opening
K859500805-01
E-Box Cover Assembly (Includes two terminal blocks, mounting plate, retention hardware)
K859501414
In-Line E-Box Coupler Kit
G-KIT-EC180
90-Degree E-Box Coupler Kit
G-KIT-EC90
Extension Box Spacer Kit
G-KIT-EXTB
Single Trunnion Kit
G-KIT-ST
Dual Trunnion Kit
G-KIT-DT
Adapter, M20 Male to 1/2" Female NPT
K231246A
Adapter, M20 Male to 3/4" Female NPT
K231247
15 W Audible Acoustic Insert
G-KIT-15WINSERT
Table 4
Choosing cable-entry devices for Equipment in Potentially Explosive Atmospheres
Models Ex
Atmospheres Cable Entry Devices (cable glands, stopping plugs, etc.)
G-SPK-XXX-D
(Ex db surface mount)
Gas
Cable entry devices shall be equipment certified as flameproof. To maintain
the ingress protection of the flameproof loludspeaker enclosure, we
recommend the cable entry device be IP66 certified.
G-SPK-XXX-E
(Ex db e surface mount)
Gas
For the flameproof loudspeaker enclosure, cable entry devices shall be
equipment certified as flameproof. To maintain the ingress protection of the
flameproof loudspeaker enclosure, we recommend the cable entry device be
IP66 certified. For the increased safety terminal enclosures (terminal boxes),
cable entry devices shall be equipment certified as increased safety and shall
maintain an IP rating of IP54.
G-SPK-XXX-D
(Ex db surface mount)
G-SPK-XXX-E
(Ex db e surface mount)
Dust
Cable entry devices for the terminal enclosures shall be equipment certified
as dust protected. To maintain the ingress protection of the loudspeaker and
terminal enclosures, the cable entry devices shall be IP6X certified.